Research & Development
Response:
(1)
OK
: Setting Successfully.
(2)
<POLL_TIME>
OK
: Response for query setting.
(3)
ERROR
: Error setting.
11.9.4 Line status query
Description:
Query the line status
Command:
AT%I0
Response:
<Event>
0 – Line de-attached, Nothing happens.
1 - Line voltage difference / absolute value are below the threshold
defined in 9.2.
3 - Line current difference / absolute value are below the threshold
defined in 9.2 (Note: when set S59=32, Modem will put 3 chars
47 47 47 to alert extra. Otherwise you can disable it by set S59
= 0)
4 - Line current difference / absolute value is over the threshold
defined in 9.2
OK
Description:
Query the RJ11 status
Command:
AT%I1
Parameter:
None
0 - No phone line is attached.
1 – A phone line is attached.
OK
Description:
Query the voltage/current value, and the value type, absolute or
Default:
100 (1 second)
Parameter:
None
2 - Line voltage difference / absolute value are over the threshold
defined in 9.2.
11.9.5 RJ11 status query
Response:
<Line status>
11.9.6 Voltage/Current value query
Page
37
of
50
Revision 1.0
2003/6 From 3JTech