Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
1 = 2nd priority tick received: Tick has been received
from 2nd priority source.
Aux Time tick
received
b1
1 = Yes: Tick interval too long (accuracy compromised).
Tick interval is too
long
b2
1 = Tick received: Tick has been received from an
external controller.
DDCS controller
b3
1 = Tick received: Tick has been received through the
master/follower link.
Master/Follower
b4
Reserved
b5
1 = Tick received: Tick has been received through the
drive-to-drive link.
D2D
b6
1 = Tick received: Tick has been received through
fieldbus interface A.
FbusA
b7
1 = Tick received: Tick has been received through
fieldbus interface B.
FbusB
b8
1 = Tick received: Tick has been received through the
embedded fieldbus interface.
EFB
b9
Reserved
b10
1 = Tick received: Tick has been received from the
control panel, or Drive Composer PC tool connected to
the control panel.
Panel link
b11
1 = Tick received: Tick has been received from Drive
Composer PC tool through an FENA module.
Ethernet tool link
b12
1 = Tick received: Tick has been set by parameters
…
Parameter setting
b13
1 = RTC time in use: Time and date have been read from
the real-time clock.
RTC
b14
1 = Drive on-time in use: Time and date are displaying
drive on-time.
Drive On-Time
b15
1 = 1
0000h…FFFFh
0 / uint16
Specifies an ID number for the drive. The ID can be read
by an external controller through DDCS, for example,
for comparison with an ID contained by the controller's
application.
Drive ID number
96.31
1 = 1 / 1 = 1
ID number.
0...32767
No sync / NA1
If the master/follower functionality is used for position
control, this parameter must be set to DDCS sync both
in master and follower drives to avoid time level
drifting.
Kernel sync mode
96.35
0
Synchronization not active.
1
Synchronization active.
0 μs / NA1
Defines a time level offset for master/follower
synchronization (when synchronization is enabled by
Kernel sync offset
96.36
1 μs / 1 = 1 μs
Offset for master/follower synchronization.
-124.0 ... 124.0 μs
522 Parameters
Summary of Contents for ACS880 N5700 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Page 2: ......
Page 4: ......
Page 22: ...22 ...
Page 28: ...28 ...
Page 32: ...32 ...
Page 60: ...60 ...
Page 546: ...546 ...
Page 604: ...604 ...
Page 626: ...626 ...
Page 640: ...640 ...
Page 660: ...660 ...