Micro Tracker Reference Guide FW 1.7 V1.1
Page 15 of 39
11th october 2018
Restricted distribution
The
NOTIFICATION
message associated to this command is shown below.
Reading parameter value response
Byte 0
Byte 1
Byte 2-5
Status
•
0x00: success
•
0x01: Invalid payload
•
0x02: Invalid Parameter ID
Parameter ID
Parameter Value.
Please check the status before taking
this value in consideration
Example:
To read the value of parameter ID 0x05. The write command 0x0005 should be sent.
A notification will be received in response, containing the parameter value: 0x000500000001.
4.3.7
Tracker Operational modes
4.3.7.1
Introduction
The
Client application
can change and retrieve the tracker operational mode by sending either a
WRITE_REQ
or a
READ_REQ
using the following
Abeeway primary service
.
Abeeway Primary Service (UUID 00008A45-1212-efde-1523-785feabcd123)
Operational mode Characteristic
UUID
Permission
0000
2741
-1212-efde-1523-785feabcd123
WRITE_REQ
READ
The
Client application
should first discover the
Abeeway Primary service
(UUID: 0000
8A45
-1212-efde-1523-
785feabcd123). This service supports a writable and notifiable characteristic called
Operational mode
Characteristic
with UUID: 0000
2741
-1212-efde-1523-785feabcd123.
4.3.7.2
Change the operational mode
The
Client application
can change the operational mode by sending a write request (
WRITE_REQ
) containing
the new operational mode value.