3.3.4
INIT – initialization
With the command INIT all paramters of this command set are set to the default values. After that
you can save the settings with the command VSAVE.
Input format:
INIT
<CR>
Output (example):
ACK
<CR>
3.3.5
LAA – LED automatic activity
The leds can be controlled by the reader or over the interface. You can set it up with the command LAA.
If the reading settings CN=1, CID=1, CE=1 (when SI=0), MD=0 and LAA=0 are set, the reader beeps
and flashes after successful reading. This setting makes sense when reader is used with HID setting.
Input format:
LAA
<SP>
parameter
<CR>
Output (example):
0
<CR>
Parameter:
PARAMETER
FUNCTION
0
controlled by reader
1
manual controlling
Note:
If automatic LED control is active (LAA = 1), it delays processing
the following command until switching the LED is over. If several
reading or writing accesses to the transponder are planed,
switch this function off (LAA = 0).