Delete a keypad code (Function 84) 

9999

#

84

#

code

#

Pass code

Function 

code

Code to be deleted

 

 

Delete all keypad codes (Function 84) 

9999

#

84

*

#  

 

Set Automatic Triggering times 

 

This feature is useful to automatically trigger electric gates at pre-set times of the day or night. For 
gates not set on “auto-closing”, this can be used to have opened and closing times with 
momentary triggers. For gates o

n “auto-closing”, this feature can be used with latching control, 

again to hold gates open during certain times. 

1234

#

1

#

day,day,day

#

time1

#

USER 
passcode

Command:

1

=trigger relay 1

2

=latch relay 1

3

=unlatch relay 1

4

=trigger relay 2

5

=latch relay 2

6

=unlatch relay 2

Enter time in 24hr format (no colon)

Select days (up to 7)
3 digit format, separate with commas.
E.g. mon,tue,wed,thu,fri

 

Example:  
For gates on step-by-step operation, to automatically close every night at 10pm send SMS: 

1234

#

1

#

sun,mon,tue,wed,thu,fri,sat

#

2200

For gates on automatic closing, to hold open between 8am and 7pm, send SMS: 

1234

#

2

#

sun,mon,tue,wed,thu,fri,sat

#

0800

# and then a second SMS: 

1234

#

3

#

sun,mon,tue,wed,thu,fri,sat

#

1900

 
Note: Up to 40 events can be stored. 
 

Delete ALL Automatic Triggering times 

 

1234

*

 

 
 
 
 
 
 
 

Summary of Contents for BFT-GSM-5ABK/3GE

Page 1: ...SM 5EDK 3GE GSM 5EDF 3GE GSM 5EDFK 3GE GSM 5ABP 3GE GSM 5ABPK 3GE GSM 5iB 3GE GSM 5iBK 3GE GSM 5HSK2 3GE GSM 5HSK3 3GE GSM 5HSK4 3GE GSM 5HSK5 3GE GSM 5HSK6 3GE GSM 5HSK7 3GE GSM 5HSK8 3GE GSM 5HSK9 3GE GSM 5HSK10 3GE GSM 5BEK 3GE BFT GSM 5ABK 3GE GSM 5BEK 3GE Manual Version 1 Save time scan the code below and watch the installation video ...

Page 2: ...ss Control Pg 9 Internal Clock Pg 9 Winter Summer Daylight Saving Pg 10 Do Not Disturb Pg 10 Out of Hours Pg 10 Programming Keypad Codes Permanent Codes Pg 11 Temporary Codes Pg 11 Time Restricted Codes Pg 11 Delete a Code Pg 12 Delete All Codes Pg 12 Set Automatic Triggering Times Pg 12 Delete all triggering times Pg 12 Notification Number Pg 13 Complete List of Parameters Pg 13 Using the Interco...

Page 3: ...blets and will not work in the unit Power TIP Most technical calls received are due to installers using CAT5 or alarm cable to power the unit Neither are rated to carry enough power 2 amp peak Please use following cable Up to 2 metres 6 feet Use minimum 0 5mm2 20 gauge Up to 4 metres 12 feet Use minimum 0 75mm2 18 gauge Up to 8 metres 24 feet Use minimum 1 0mm2 16 gauge Using insufficient power ca...

Page 4: ...ide View Flush Panels Call Button Optional keypad module Remove Side View Flush with surface Tip Use appropriate fixings to ensure the intercom cannot be removed from the wall Do not remove the protective film until the system is fully installed and working Protective coverings are there to protect the intercom from scratches and marks during installation Antenna height is best higher than interco...

Page 5: ... COM N O Out 1 Out 2 eg 24v ac dc Antenna connection 12v dc output not used Pre wired to push button Optional exit button triggers output 1 for programmed time 24v DC Optional gate position limit switch Relay outputs Signal LED CPU Power Micro SIM Insert this way Please ensure the SIM card is a 2G compatible Micro SIM card The SIM may also be 3G and 4G capable as well as long as both the SIM and t...

Page 6: ... ensure the antenna is connected before switching on the power Once the power is switched on the power LED should illuminate Power LED CPU LED Signal LED Searching 1 bar signal 2 bars signal 3 bars signal 4 bars signal System booted Booting GSM modem TIPS My GSM LED is still searching Check the SIM card is registered and can make a call in a phone Check the SIM card is seated correctly Power off c...

Page 7: ...unction code add number Data Button number 1 10 Telephone number position 1 4 TIP 111 Telephone number 1 112 Telephone number 2 113 Telephone number 3 E g 9999 111telephonenumber1 112telephonenumber2 113telephonenumber3 Signal level 19 9999 1110 987654321 11098765 4321 OK Send the SMS 20 as shown to the SIM card number of the intercom The unit should reply with a reception level between 1 and 31 2...

Page 8: ... to the button number as shown Example To program second number for button 8 enter string 9999 182telephonenumber TIP For button 10 use zero as the button location e g 101 button 10 first number 102 button 10 second number etc 10 9 8 9 7 6 5 4 3 2 1 9 8 7 4 3 2 171 button 7 tel no 1 172 button 7 tel no 2 173 button 7 tel no 3 174 button 7 tel no 4 191 button 9 tel no 1 192 button 9 tel no 2 193 bu...

Page 9: ... without answering and activate the output relay 1 all within a few seconds Tip The intercom only compares the last 6 digits of the number with memory therefore it is not necessary to enter country codes To add numbers send the following SMS up to 4 numbers can be entered in the same SMS 9999 72telephonenumber 72telephonenumber 72telephonenumber 72telephonenumber Tip Even if a number is stored as ...

Page 10: ... as follows 9999 21 day day day time1 time2 Pass code Function code Enter start and end time in 24hr 4 digit format no colon and separate with comma e g 0800 2300 Select days up to 7 3 digit format separate with commas E g mon tue wed thu fri Example to program the unit to be active between 8 00 am and 11pm for all days send the following SMS 9999 21mon tue wed thu fri sat sun 0800 2300 Out of Hou...

Page 11: ...de Function 82 9999 82 hours code Pass code Function code Can be between 1 168 hours 4 digit code Example To program a code 4321 to be active for 8 hours send SMS 9999 82 8 4321 Programing a Time Restricted Code Function 83 9999 83 day day day time1 time2 code Pass code Function code Enter start and end time in 24hr 4 digit format no colon and separate with comma e g 0800 2300 Select days up to 7 ...

Page 12: ...pen during certain times 1234 1 day day day time1 USER passcode Command 1 trigger relay 1 2 latch relay 1 3 unlatch relay 1 4 trigger relay 2 5 latch relay 2 6 unlatch relay 2 Enter time in 24hr format no colon Select days up to 7 3 digit format separate with commas E g mon tue wed thu fri Example For gates on step by step operation to automatically close every night at 10pm send SMS 1234 1 sun mo...

Page 13: ...ng password 9999 02 Change access control password SMS control of relays or non stored numbers can call intercom enter code to activate output 1 1234 03 Change monitoring mode password user can call the intercom enter this pass code to listen in and speak 5555 Dial out numbers 1XY Store dialling out numbers X button number 1 9 0 for button 10 Y number dialled 1 4 phone number N A 1XY Delete a dial...

Page 14: ...iggered N A 79text Where text is the content of the message to be sent E g Gates Opened or Door Opened This will be sent on closing of any output relay N A 80 When 1 this function is disabled Set to 2 to enable N A Caller ID features 72number Store caller ID number Max 14 digits Only last 6 digits compared N A 73number Delete caller ID number N A 73 Delete all caller ID numbers N A Latching Disabl...

Page 15: ...he intercom It will recognise the number terminate the call without answering and automatically trigger relay 1 Opening Gates Door from a non stored number If a phone number is not stored when that phone calls the intercom the intercom will answer the call The user can then enter a 4 digit passcode to trigger relay 1 default user passcode 1234 Phone 1 Phone 2 Phone 3 Dialling 1 2 3 4 5 6 7 8 9 0 R...

Page 16: ...s easy as well as other control features Android Setup Apple Setup 1 Install and launch the app Press SETTINGS as shown 2 Press the PHONE NUMBER button 3 Enter the phone number of the intercom SIM card Note If the default engineers code or user code have been changed from their defaults then please change as required in the relevant section above Now you should be ready to use the app ...

Page 17: ... sends SMS to intercom for output 2 LATCH HOLD OPEN Press to hold ON the relay UNLATCH UNHOLD Press to release a latched relay allow gates to close NOTIFICATION OPTION Press to setup SMS notifications when gates are triggered HOME TIME SETTINGS Features such as auto triggering do not disturb activity log KEYPAD SETTINGS Create or delete keypad codes temporary codes time restricted codes ...

Page 18: ...desirable to call an alternate number after the do not disturb watershed time If a phone number is entered in this screen then the intercom will call the previously programmed standard numbers during normal operating times and this alternate phone number after hours TIP For multi button panels repeat entering the out of hours number for each active button on the panel see button numbers in this ma...

Page 19: ... at a pre set time or close every night at a pre set time Tip Up to 4 auto trigger events per day can be stored Check signal strength on your intercom Level 1 31 Must be above 14 for successful operation Check stored numbers Will send SMS reply with O for dial out numbers and I for dial in caller ID access numbers Check the state of both relays ON or OFF ON latched open state Check status of gate ...

Page 20: ...g Timed Code Tip For time restricted codes Temporary Code Tip Enter code and time in hours 1 168 Code auto deletes after time expires Delete Code Tip Delete last saved temp or time restricted code or any known code General Tips Permanent codes can be programmed for relay 1 or relay 2 Temporary and scheduled codes can only be programmed for relay 1 ...

Page 21: ...S notifications when gates are triggered OPEN GATES Press to trigger the relay speed dials intercom for output 1 and sends SMS to intercom for output 2 UNLATCH UNHOLD Press to release a latched relay allow gates to close TIME SETTINGS Features such as auto triggering do not disturb activity log set clock etc KEYPAD SETTINGS Create or delete keypad codes temporary codes time restricted codes ...

Page 22: ... colon For commercial installations sometimes it is desirable to call an alternate number after the do not disturb watershed time If a phone number is entered in this screen then the intercom will call the previously programmed standard numbers during normal operating times and this alternate phone number after hours TIP For multi button panels repeat entering the out of hours number for each acti...

Page 23: ... at a pre set time or close every night at a pre set time Tip Up to 4 auto trigger events per day can be stored Check stored numbers Will send SMS reply with O for dial out numbers and I for dial in caller ID access numbers Check last 20 users who triggered gates including keypad codes used with date and time Check signal strength on your intercom Level 1 31 Must be above 14 for successful operati...

Page 24: ...ke lock 7 secs for mag lock 0 for latching Delete Code Tip Delete last saved temp or time restricted code or any known code General Tips Permanent codes can be programmed for relay 1 or relay 2 Temporary and scheduled codes can only be programmed for relay 1 Temporary Code Tip Enter code and time in hours 1 168 Code auto deletes after time expires ...

Page 25: ... card in the intercom and it will reply with a log of the last 20 events in the following format Send the SMS as shown and the unit will reply showing the status of the input limit switch if used and the relay This example shows that the input sensor is in OPEN state Relay 1 is OFF and Relay 2 is latched ON TIP If there is not a physical limit switch fitted to the door or gate then the status inpu...

Page 26: ...requency of operation should be any one of international quad band standards 850 900 1800 1900 MHz Check the reception is good Poor reception is not sufficient Check voltage at the intercom is minimum 23V and that the cable from power supply to intercom is less than 15 feet and that the cable thickness is sufficient Power off remove the SIM use fine sand paper to lightly sand the SIM pads and cont...

Page 27: ...phone check the settings on the phone in question under DTMF tones Failure of DTMF tones to operate correctly is also a symptom of low reception Check steps above on improving reception Try pressing the buttons longer when attempting to activate the gates or door Q The keypad confirmation bleeps when I enter my code but the gates or door lock does not open A Check wiring The keypad relay should be...

Page 28: ...new feature to disable latching by DTMF 24v dc power supply Jan 2017 Radio Function GSM 850 824MHz 848MHz GSM 900 880MHz 915MHz DCS 1800 1710MHz 1785MHz PCS 1900 1850MHz 1910MHz WCDMA Band I 1920MHz 1980MHz WCDMA Band VIII 880MHz 915MHz RF Power 32 86dBm for GSM900 29 89 for DCS1800 23 77dBm for WCDMA Band I 23 66dBm for WCDMA Band VIII The device complies with RF specifications when the device us...

Page 29: ...elocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Caution Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipme...

Reviews: