Message string format is:
Host sends:
[Dir] [01] [01] [FF][05] [Chk]
Coin s. responds:
[01] [6] [Dir] [00] [data 1] [data 2] . . . [data 6] [Chk]
42
20 x 3 byte of memory!
43
Special case write command
Data string description:
-
data 1 Measured coin parameter 1, AM1
-
data 2 Measured coin parameter 2, PH1
-
data 3 Measured coin parameter 3, AM2
-
data 4 Measured coin parameter 4, PH2
-
data 5 Measured coin parameter 5, PI3
-
data 6 Measured coin parameter 6, DIM
The example of message string after insertion of one Euro coin for coin selector
AL66
(
address 2
) is:
Host sends:
[02] [01] [01] [FF][05] [F8]
Coin s. responds:
[01] [6] [02] [00] [8A] [80][8C] [5C] [AB] [8A] [D0]
Coin measured parameters(
data
) are available for read till next coin insertion.
This instruction is used by our coin programming software.
6.5.4.1.5
Command 255 mode 6, Up-grade FLASH
This command is used to up-grade coin selector FLASH program memory.
User can up-grade coin selector in cases when he knead some new function or improvement, which where not
available at the moment when coin selector was purchased. This instruction is used by our coin selector
programming software and generally is not useful to most users. Additional information are available on request.
Up-grade files are encrypted in factory and decryption is done internally by monitor program of coin selector.
Coin selector will accept only correct type of up-grade file!
6.5.4.1.6
Command 255 mode 7, Factory reset
This command will set all coin selector data to initial factory programming values!
Warning: This could lead to unwanted coin selector function if different coin, inputIoutput or user setting data
where programmed!
The example of message string reset the factory settings is:
Host sends:
[02] [01] [01] [FF][07] [F6]
Coin s. responds:
[01][00][02][00] [FD]
ACK
After that, coin selector must be switched off/on!
6.6
Error Codes
PLEASE NOTE:
default status does not include Error Codes. The coin acceptor can be preset for error code
transmission IF REQUESTED WHEN PLACING THE ORDER FOR THE COIN ACCEPTOR(S).
ERROR CODE LIST
Else, make use of the Alberici Coin Selector programming software to enable transmission. Tick the checkbox
in the menu “Config. CCTalk","Settings"/"Activate Error Events in Coins Test", then press “Write data” key to
transfer the instruction into the coin acceptor.
Summary of Contents for AL66 FG ARM
Page 1: ...AL66 FG ARM Pulse mod ccTalk COIN ACCEPTOR Operator s Manual Rev 2 01 User Manual...
Page 2: ......
Page 34: ......