Camera Link registers
63
Goldeye Camera Link Register Controls Reference V1.0.0
RegSensorTemperatureSetpointActive
TEC active setpoint, it displays the active setpoint.
RegSensorTemperatureSetpointMode
Controls the setpoint mode for the TEC. Allows to set either the manual or
automatic selection of setpoints.
Activates the currently selected
SensorTemperatureSetpoint
.
Register name
RegSensorTemperatureSetpointActive
Register type
IntReg
Access mode
R
Address
0x000B0164
Length (Bytes)
4
Bits used
31..0
Register name
RegSensorTemperatureSetpointMode
Register type
IntReg
Access mode
R/W
Address
0x000B005C
Length (Bytes)
4
Default
Auto
Bits used
31..0
Enumeration values:
Value
Name and description
0
Manual
Select the setpoint manually. The active setpoint is presented by
SensorTemperatureSetpointActive
and it can be changed by the
following ways
•
SensorTemperatureSetpointSelector
and
SensorTemperatureSetpointActivate
in succession
•
SensorTemperatureTargetSetpoint
in
TemperatureControlTarget
mode.
1
Auto
The setpoint is selected automatically.