Guppy PRO Technical Manual
V4.1.2
219
The ExSyncArmed flag indicates that the camera is set up for external
triggering. Even if the camera is waiting for an external trigger event the Idle
flag might get set.
Other bits in this register might be set or toggled: just ignore these bits.
Maximum resolution
This register indicates the highest resolution for the sensor and is read only.
Note
•
Excessive polling of this register may slow down the
operation of the camera. Therefore, the time between
two polls of the status register should not be less than 5
ms. If the time between two read accesses is less than 5
ms the response will be delayed.
•
Depending on shutter and isochronous settings the
status flags might be set for a very short time; thus, will
not be recognized by your application.
Register
Name
Field
Bit
Description
0xF1000100
CAMERA_STATUS
Presence_Inq
[0]
Indicates presence of this
feature (read only)
---
[1 to 23] Reserved
ID
[24 to 31] Implementation ID = 0x01
0xF1000104
---
[0 to 14] Reserved
ExSyncArmed
[15]
External trigger enabled
---
[16 to 27] Reserved
ISO
[28]
Isochronous transmission
---
[29 to 30] Reserved
Idle
[31]
Camera idle
Table 125: Advanced register: Camera status
Note
This register normally outputs the MAX_IMAGE_SIZE_INQ
Format_7 Mode_0 value.
This is the value given in the specifications tables under Picture
size (max.) in chapter