ASL Holdings Limited
19/09/2005
15
Draft Copy Version 2c
at*e2apc?
Response: *E2APC: 0,1,0,0
Power cycle the modem.
Interrogate modem:
at*e2apc?
Response: *E2APC: 1,1,0,0 (Remote Access enabled)
General
======
AT+CGMR
This command will cause the Sony Ericsson module to display its
type/version.
Response: R6A023 CXC1122528 (Example).
AT+CBST?
This command gives information regarding the cellular network bearer
channel.
Response: 0,0,1 (Autobaud rate, Asynchronous, Non transparent).
S Registers:
S0= Number of rings to answer.
Range 0-7 (Default 0 – No answer)
S2= Escape sequence character
Range 0-255 (Default 43 = +)
S3=
CR
character
Range
0-127 (Default 13 - Cntrl M)
S4=
LF
character
Range 0-127 (Default 10 - Cntrl J)
S5= Back space character
Range 0-127 (Default 8 -Backspace)
S6= Wait before blind dialling
Range 2-255 (Default 2 – 2 secs)*
S7= Wait for carrier
Range 1-255 (Default 50 – 50 secs)
S8= Comma Pause time
Range 1-255 (Default 2 – 2 secs)*
S10= Carrier loss to hang up time
Range 1-254 (Default 2 – 0.2 secs)*
* Compatibility only
Modem result codes:
Numeric
Verbose
Legend
0
OK
Command line executed without errors.