25
Name
Holding
Registers
Input
Registers
Coils
Inputs
Description
Watchdog_time
0x10
This parameter defines the time in seconds that can elapse
between the last communication and the actuation of the
watchdog. If it is set to 0, the Watchdog is disabled. Range: 0 –
65535.
Watchdog_config
0x11
This parameter defines how will actuate the watchdog if the
communications fail.
State when overflow WD
low byte
The Low Byte
is not considered. It shoud be at 0.
Config of working mode
high byte
The High Byte
is the configuration of the working mode.
0 = Defined in Watchdog predefined color/sequence.
1 = module reset.
WDT predefined color/sequence
0x14
This parameter defines the color or sequence that will be
activated when the Watchdog triggers. 0xFFFF remains with the
color / sequence previous to the alarm state.
Color/Sequence
low byte
The Low Byte
is the color if Speed=0, or sequence if Speed is
different of 0.
Speed
high byte
The High Byte:
Speed: 0 = Color Fixed. 1 to 8 = Sequence.
Start predefined color/sequence
0x15
This parameter defines the color or sequence of the Lumiplus
when Starts. 0xFFFF remains with the color / sequence previous to
the last OFF.
Color/Sequence
low byte
The Low Byte
is the color if Speed = 0; or sequence if Speed is
different of 0.
Speed
high byte
The High Byte:
speed: 0 = Color Fixed. 1 to 8 = Sequence.