Z-Wave Command Classes
Z-Wave Command Classes
Configuration
Specifications
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_ASSOCIATION_V2(On Secure)
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3(On Secure)
COMMAND_CLASS_BASIC_V2(On Secure)
COMMAND_CLASS_BATTERY(On Secure)
COMMAND_CLASS_CONFIGURATION(On Secure)
COMMAND_CLASS_DEVICE_RESET_LOCALLY(On Secure)
COMMAND_CLASS_DOOR_LOCK_V4(On Secure)
COMMAND_CLASS_DOOR_LOCK_LOGGING(On Secure)
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5(On Secure)
COMMAND_CLASS_INDICATOR_V3(On Secure)
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2(On Secure)
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3(On Secure)
COMMAND_CLASS_
POWERLEVEL
(On Secure)
COMMAND_CLASS_
USER̲CODE
(On Secure)
COMMAND_CLASS_
VERSION̲V3
(On Secure)
Mass
Outside dimensions
IN - BODY
OUT - BODY
Communication distance
Available frequency
Communication mode
Operating temperature
Operating humidity
Indicating light
Power supply
Part number
Product name
Configuration_Set(0x04)
Configuration_Report(0x06)
The format after the parameter number is the same as SET.
Configuration_Set(0x04)
Configuration_Report(0x06)
The format after the parameter number is the same as SET.
Response (0x03)
When you send this command, it beeps once and the button flashes
blue about 2 second.
Remote control (0x01)
Door Lock Mode
0x00 : Door Unsecured
0xFF : Door Secured
Outside Door Handles Mode
0x00
Inside Door Handles Mode
0x00
Door Condition
0x00
Lock Timeout Minutes
0x00
Lock Timeout Seconds
0x00
Target Door Lock Mode
0x00
Duration
0x00
Door Lock Mode
0x00 : Door Unsecured
0xFF : Door Secured
Value 0xFF
Firmware-Update over the Air (0x7A)
Indicator (0x87)
This device is capable of receiving a new firmware 'over the air'.
Target 0 : Z-Wave
Target 1 : INBODY
Target 2 : OUTBODY
Configuration Parameters
Parameter No.13
Change the device time setting.
Default : 0 [NOTE]If Default is set to 1, the following items will ignore
the set values and return to the defaults.
Size : 4
Configurable time 2000/01/01 00:00:00 ~ 2099/12/31 23:59:59
[NOTE] It cannot be set at any other time.
Default
0x38
0x6D
0x43
0x80
Parameter No.14
Change the lock settings.
Default : 0 [NOTE]If Default is set to 1, the following items will ignore
the set values and return to the defaults.
Size : 2
Pn14 Setting details
*1 When locking with OUTBODY, operation with PIN code or
IC card is required.
*2 The lock mode changes to manual (0x02).
*3 The door sensor changes to disable (0x00).
*4 No alarm when the door is forced open.
*5 If the lock mode is manual, it cannot be set to (0x01).
About 800 g
About 56.9(W) x 93.4(H) x 17.98(D) mm
About 74.8(W) x 129.3(H) x 54.5(D) mm
About 30 m (prospect)
922.5 / 923.9 / 926.3 MHz
Z-Wave®
For alkaline batteries 0 to +50 ˚C
For lithium batteries -20 to +50 ˚C
RH 20 to 85% (no condensation)
Red and blue (IN - BODY)
White , red , green (OUT - BODY)
AA type x 4
Smart Lock
ZSL10
7
6
5
4
3
2
1
0
Command = DOOR_LOCK_OPERATION_SET
Command Class = COMMAND_CLASS_DOOR_LOCK
Door Lock Mode
7
6
5
4
3
2
1
0
Command Class = COMMAND_CLASS_DOOR_LOCK
Command = DOOR_LOCK_OPERATION_REPORT
Door Lock Mode
Outside Door Handles Mode Inside Door Handles Mode
Target Door Lock Mode
Duration
Door Condition
Lock Timeout Minutes
Lock Timeout Seconds
7
6
5
4
3
2
1
0
Command Class = COMMAND_CLASS_INDICATOR
Command = INDICATOR_SET
Value
Setting name
Value
Detail
Default
0
left hanging door
1
right hanging door
○
00
mute
01
small
10
medium
○
11
large
00
automatic locking - short
○
01
automatic locking - long
10
manual
11
manual *1
0
disable
1
enabled
○
0
main
○
1
sub *2,*3
00
disable
01
enabled
○
10
enabled *4
11
Not used
0
Continuous-unlocking
○
1
automatic locking *5
Motor torque
0
normal
○
1
high
Volume
Setting the hanging
Lock mode when unlocking
thumb turn
Door sensor
O/C button
Lock mode
Main/sub switching
for double lock
7
6
5
4
3
2
1
0
Default
…
Device time(LSB)
Command Class = COMMAND_CLASS_CONFIGURATION
Command = CONFIGURATION_SET
Parameter Number
Reserved
Size
Device time(MSB)
…
7
6
5
4
3
2
1
0
Default
Setting the
hanging
O/C
button
Main/sub
switching for
double lock
0
Lock mode
when
unlocking
thumb turn
Moter
torque
0
0
0
0
Command Class = COMMAND_CLASS_CONFIGURATION
Command = CONFIGURATION_SET
Parameter Number
Reserved
Size
Volume
Lock mode
Door sensor