background image

Z-Wave Command Classes

Z-Wave Command Classes

Configuration

Specifications

COMMAND_CLASS_ZWAVEPLUS_INFO_V2

COMMAND_CLASS_TRANSPORT_SERVICE_V2

COMMAND_CLASS_SECURITY

COMMAND_CLASS_SECURITY_2

COMMAND_CLASS_SUPERVISION

COMMAND_CLASS_ASSOCIATION_V2(On Secure)

COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3(On Secure)

COMMAND_CLASS_BASIC_V2(On Secure)

COMMAND_CLASS_BATTERY(On Secure)

COMMAND_CLASS_CONFIGURATION(On Secure)

COMMAND_CLASS_DEVICE_RESET_LOCALLY(On Secure)

COMMAND_CLASS_DOOR_LOCK_V4(On Secure)

COMMAND_CLASS_DOOR_LOCK_LOGGING(On Secure)

COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5(On Secure)

COMMAND_CLASS_INDICATOR_V3(On Secure)

COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2(On Secure)

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3(On Secure)

COMMAND_CLASS_

POWERLEVEL

(On Secure)

COMMAND_CLASS_

USER̲CODE

(On Secure)

COMMAND_CLASS_

VERSION̲V3

(On Secure)

Mass

Outside dimensions

IN - BODY
OUT - BODY

Communication distance

Available frequency

Communication mode

Operating temperature

Operating humidity

Indicating light

Power supply

Part number

Product name

Configuration_Set(0x04)

Configuration_Report(0x06)

The format after the parameter number is the same as SET.

Configuration_Set(0x04)

Configuration_Report(0x06)

The format after the parameter number is the same as SET.

Response (0x03)

When you send this command, it beeps once and the button flashes

blue about 2 second.

Remote control (0x01)

Door Lock Mode

    0x00 : Door Unsecured

    0xFF : Door Secured

Outside Door Handles Mode

    0x00

Inside Door Handles Mode

    0x00

Door Condition

    0x00

Lock Timeout Minutes

    0x00

Lock Timeout Seconds

    0x00

Target Door Lock Mode

    0x00

Duration

    0x00

Door Lock Mode

    0x00 : Door Unsecured

    0xFF : Door Secured

Value    0xFF

Firmware-Update over the Air (0x7A)

Indicator (0x87)

This device is capable of receiving a new firmware 'over the air'.

    Target 0 : Z-Wave

    Target 1 : INBODY

    Target 2 : OUTBODY

Configuration Parameters

Parameter No.13

Change the device time setting.

Default : 0     [NOTE]If Default is set to 1, the following items will ignore

                                       the set values and return to the defaults.

Size : 4

Configurable time   2000/01/01 00:00:00 ~ 2099/12/31 23:59:59

[NOTE] It cannot be set at any other time.

Default

  0x38

  0x6D

  0x43

  0x80

Parameter No.14

Change the lock settings.

Default : 0     [NOTE]If Default is set to 1, the following items will ignore

                                       the set values and return to the defaults.

Size : 2

Pn14   Setting details

*1 When locking with OUTBODY, operation with PIN code or

     

IC card is required.

*2 The lock mode changes to manual (0x02).

*3 The door sensor changes to disable (0x00).

*4 No alarm when the door is forced open.

*5 If the lock mode is manual, it cannot be set to (0x01).

About 800 g

About 56.9(W) x 93.4(H) x 17.98(D) mm

About 74.8(W) x 129.3(H) x 54.5(D) mm

About 30 m (prospect)

922.5 / 923.9 / 926.3 MHz

Z-Wave®

For alkaline batteries      0 to +50 ˚C

For lithium batteries   -20 to +50 ˚C

RH 20 to 85% (no condensation)

Red and blue (IN - BODY)

White , red , green (OUT - BODY)

AA type x 4

Smart Lock
ZSL10

7

6

5

4

3

2

1

0

Command = DOOR_LOCK_OPERATION_SET

Command Class = COMMAND_CLASS_DOOR_LOCK

Door Lock Mode

7

6

5

4

3

2

1

0

Command Class = COMMAND_CLASS_DOOR_LOCK

Command = DOOR_LOCK_OPERATION_REPORT

Door Lock Mode

Outside Door Handles Mode Inside Door Handles Mode

Target Door Lock Mode

Duration

Door Condition

Lock Timeout Minutes

Lock Timeout Seconds

7

6

5

4

3

2

1

0

Command Class = COMMAND_CLASS_INDICATOR

Command = INDICATOR_SET

Value

Setting name

Value

Detail

Default

0

left hanging door

1

right hanging door

00

mute

01

small

10

medium

11

large

00

automatic locking - short

01

automatic locking - long

10

manual

11

manual *1

0

disable

1

enabled 

0

main

1

sub *2,*3

00

disable

01

enabled 

10

enabled *4

11

Not used

0

Continuous-unlocking

1

automatic locking *5

Motor torque

0

normal

1

high

Volume

Setting the hanging

Lock mode when unlocking

thumb turn

Door sensor

O/C button

Lock mode

Main/sub switching

for double lock

7

6

5

4

3

2

1

0

Default

Device time(LSB)

Command Class = COMMAND_CLASS_CONFIGURATION

Command = CONFIGURATION_SET

Parameter Number

Reserved

Size

Device time(MSB)

7

6

5

4

3

2

1

0

Default

Setting the

hanging

O/C

button

Main/sub

switching for

double lock

0

Lock mode

when

unlocking

thumb turn

Moter

torque

0

0

0

0

Command Class = COMMAND_CLASS_CONFIGURATION

Command = CONFIGURATION_SET

Parameter Number

Reserved

Size

Volume

Lock mode

Door sensor

Reviews: