11
RS232 and Telnet Commands
Command
Action
?
Print Help Information
HELP
Print Help Information
STATUS
Print System Status And Port Status
PON
Power On, System Run On Normal State
POFF
Power Off, System Run On Power Save State
IR ON/OFF
Set System IR Control On Or Off (Only for IR Extension)
KEY ON/OFF
Set System KEY Control On Or Off
BEEP ON/OFF
Set Onboard Beep On Or Off
RESET
Reset System To Default Setting,
Should Type ‘Yes’ To Confirm, ‘No’ To Discard
DBG TX xx OSP SRC
HDCP version follows source
xx=01-04 (input)
xx=00, all inputs 01-04
DBG TX xx OSP SNK
HDCP version follows sink
xx=output 01-04 (output)
xx=00, all outputs 01-04
OUT xx ON/OFF
Set OUTPUT:xx On Or Off
OUT xx CSC cc
Set OUTPUT: xx Color Space Convert Mode
xx=00: Select All INPUT Port
xx=[01...04]: Select One INPUT Port
cc=OFF: Disable Convert Function
cc=420: Always Convert 6G 444 Format To 3G 420
cc=AUTO: Auto Convert 6G 444 Format To 3G 420
When Detect Sink Not Support 6G 444
OUT xx FR yy
Set OUTPUT:xx From INPUT:yy
EDID xx CP yy
Set Input:xx EDID Copy From Output:yy
EDID xx DF zz
Set Input: xx EDID To Default EDID zz
xx=00: Select All INPUT Port
xx=[01...04]: Select One INPUT Port
yy=[01...04]: Select One OUTPUT Port