Section 8. Operation
456
8.8.4.4 Formatting Drives
CPU:, USR:, USB:, and CRD: drives can be formatted individually. Formatting
a drive erases all files on that drive. If the currently running user program is
found on the drive to be formatted, the program will cease running and any
SRAM data associated with the program are erased. Drive formatting is
performed through datalogger support software
Format
(p. 539)
command.
8.8.5 File Management in CR3000 Memory
As summarized in table File Control Functions
(p. 456),
files in CR3000 memory
(program, data, CAL, image) can be managed or controlled with datalogger
support software
(p. 90),
the CR1000KD keyboard/display (see Keyboard Display
— Details
(p. 483))
, Web API
or CoraScript
(p. 533).
Use of CoraScript is
described in the LoggerNet software manual, which is available at
www.campbellsci.com. More information on file attributes that enhance
datalogger security, see the Security — Overview
section.
File Control Functions
File Control Functions
Accessed Through
Sending programs to the CR3000
Program Send
1
, File Control Send
2
, DevConfig
3
,
CR1000KD keyboard/display, or powerup.ini with a
Campbell Scientific mass storage device or memory
card
4,5
, web API
(p. 475)
HTTPPut (Sending a File to a
Datalogger)
Setting program file attributes. See File Attributes (p. 457)
File Control
2
; power-up with Campbell Scientific mass
storage device or memory card
5
, FileManage()
instruction
6
, web API FileControl
Sending an OS to the CR3000. Reset CR3000 settings.
DevConfig
3
Send OS tab; DevConfig
3
File Control tab;
Campbell Scientific mass storage device or memory
card
5
Sending an OS to the CR3000. Preserve CR3000
settings.
Send
1
; DevConfig
3
File Control tab; power-up with
Campbell Scientific mass storage device or memory
card with default.cr3 file
5
, web API HTTPPut
(Sending a File to a Datalogger)
Formatting CR3000 memory drives
File Control
2
, power-up with Campbell Scientific mass
storage device or memory card
5
, web API FileControl
Retrieving programs from the CR3000
Retrieve
7
, File Control
2
, keyboard with Campbell
Scientific mass storage device or memory card
4
, web
API NewestFile
Prescribes the disposition (preserve or delete) of old
data files on Campbell Scientific mass storage device or
memory card
File Control
2
, power-up with Campbell Scientific mass
storage device or memory card
5
, web API
(p. 475)
FileControl
Deleting files from memory drives
File Control
2
, power-up with Campbell Scientific mass
storage device or memory card
5
, web API FileControl
Summary of Contents for CR3000 Micrologger
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ......
Page 30: ......
Page 34: ......
Page 36: ......
Page 96: ......
Page 485: ...Section 8 Operation 485 8 11 2 Data Display FIGURE 110 Keyboard and Display Displaying Data ...
Page 487: ...Section 8 Operation 487 FIGURE 112 CR1000KD Real Time Custom ...
Page 491: ...Section 8 Operation 491 FIGURE 116 Keyboard and Display File Edit ...
Page 496: ......
Page 502: ......
Page 564: ...Section 11 Glossary 564 FIGURE 126 Relationships of Accuracy Precision and Resolution ...
Page 566: ......
Page 594: ......
Page 598: ......
Page 600: ......
Page 602: ......
Page 624: ......
Page 642: ......
Page 643: ......