TX321 Transmitter
28
7.5.4.9 Timed Offset
Timed Offset
is assigned by NESDIS and is a string variable in the format of
“hh_mm_ss”, where hh is hours and usually 00, mm is minutes, and ss is
seconds.
7.5.4.10 Random Interval
Random Interval
is a string variable in the format of “hh_mm_ss” where hh
and ss are usually zero and mm is 30 or 45.
7.5.4.11 GOESSetup() Example
CRBasic Example 7-2. GOESSetup() Instruction
Public
setup_RC, setup as Boolean
Sub
Gsetup
GOESSetup
(setup_RC,&H12345678,10,195,300,0,100,"0_01_00_0" ,"0_16_20" ,"1_0_0" )
If
setup_RC = 0
Then
setup = false
EndSub
BeginProg
setup = true
Scan
(10,Sec,0,0)
If
setup
Then Call
Gsetup
NextScan
EndProg
8. Troubleshooting/Diagnostics
8.1 Fail-safe Conditions
The built-in fail-safe processor helps prevent malfunctioning transmitters from
interfering with other transmissions. It disables satellite transmissions if one of
these events occur:
•
A transmission occurs
too close (≤ 30 s) to the previous transmission
•
A transmission continues for an excessive amount of time (≥ 105
seconds for GOES, ≥ 90 seconds for EUMETSDAT)
•
Supply battery voltage is below 10.5 VDC
The fail-safe operation is independent of the main processor and cannot be
disabled.
Summary of Contents for TX321
Page 1: ...TX321 Transmitter Revision 5 19 Copyright 2000 2019 Campbell Scientific ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 46: ......
Page 48: ......
Page 56: ......
Page 82: ......
Page 84: ...AppendixE Meteosat F 2 FIGURE F 2 DCPRS and CGMS certificate ...
Page 85: ...AppendixE Meteosat F 3 FIGURE F 3 EUMETSAT certificate ...