CPE Side: (use the correct MAC address for the local CO unit) 
 

gci 

srcnet 172.16.1.2 255.255.255.0 

ipset 192.168.2.11 255.255.255.0 172.16.1.1 

ceschset 1 1 172.16.1.1 00:02:AB:xx:xx:xx 

cespwidset 1 1 1 

pktsize 1 0 

jitterbd 1 1   

ceschclkset 1 0 

cesfe1mode 1 1 

cesfe1crc 1 1 

cesfe1tsmap 1 x000001FE 

lanset 0 

lanset 1 7 

csave 

 

3.11.3 Notes on Fractional E1 Operation 

 

If IPM carries E1 as 'unframed', then it becomes transparent (SAToP). As long as the equipment on both 

sides of IPM equipment have the same framing, then there will be no alarms. However, the advantage of 
using framing (CESoPSN) is that the data bandwidth can be reduced considerably by sending only the 
payload, especially over a satellite link. You must make sure the right timeslots are enabled and match the 
crc4 if enabled or not (cesfe1crc). Duplicate these settings on both IPM4SE units. 

 

For the hex to timeslot bit mask, each TS is represented by a bit: 

TS bits : 11111111111111111111111111111111 

TS #      33222222222211111111110000000000 

 31~0     10987654321098765432109876543210 

 

If we breakup into octets, then we can assign hex values: 

1111|1111|1111|1111|1111|1111|1111|1111 

  F |  F |  F |  F |  F |  F |  F |  F 

 

So, if we want to enable fifteen timeslots, starting with TS1: 

 

0000|0000|0000|0000|1111|1111|1111|1110 

  0 |  0 |  0 |  0 |  F |  F |  F |  E 

 

The 

cesfe1tsmap

 value would be 

x0000FFFE

 

 

If the timeslot range always starts at TS1, this table will work for you: 

hex map    no. of TS 
x00000002 = 1 
x00000006 = 2 
x0000000E = 3 
x0000001E = 4 
x0000002E = 5 
x0000006E = 6 
x000000FE = 7 

x000001FE = 8 
x000002FE = 9 
x000006FE = 10 
x00000FFE = 11 
x00001FFE = 12 
x00002FFE = 13 
x00006FFE = 14 
x0000FFFE = 15 

x0001FFFE = 16 
x0002FFFE = 17 
x0006FFFE = 18 
x000FFFFE = 19 
x001FFFFE = 20 
x002FFFFE = 21 
x006FFFFE = 22 
x00FFFFFE = 23 

x01FFFFFE = 24 
x02FFFFFE = 25 
x06FFFFFE = 26 
x0FFFFFFE = 27 
x1FFFFFFE = 28 
x2FFFFFFE = 29 
x6FFFFFFE = 30 
xFFFFFFFE = 31 

 

Summary of Contents for IPM-4SE

Page 1: ...IPM 4SE 4 Port E1 IP Multiplexer ...

Page 2: ......

Page 3: ...m alleges that CTC Union Technologies was negligent regarding the design or manufacture of said product TRADEMARKS Microsoft is a registered trademark of Microsoft Corp HyperTerminal is a registered trademark of Hilgraeve Inc FCC WARNING This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to ...

Page 4: ...odels IPM 4SE AC IPM 4SE DC This document is the current official release manual Please check CTC Union s website for any updated manual or contact us by E mail at sales ctcu com Please address any comments for improving this manual or to point out omissions or errors to marketing ctcu com For technical support for this product or other CTC Union products contact our support staff at techsupport c...

Page 5: ...t 10 100M Ethernet Port for Telnet or SNMP based Management 13 3 3 REAR PANEL INTRODUCTION 14 3 3 1 WAN Interface 14 3 3 2 AC Power Socket and Switch On Off switch for AC 14 3 3 3 DC Power Socket and Switch On Off switch for DC 14 3 4 LOOPBACK MODE 14 3 5 IP CONFIGURATION 14 3 6 INTERFACE CONFIGURATION 14 3 7 FAULT REPORT 15 3 8 SAVE CONFIGURATION 15 3 9 COMMAND LINE INTERFACE SETUP 15 3 9 1 Using...

Page 6: ...Table of Contents ii ...

Page 7: ...cket loss concealment PLC Since TDM data is delivered at a constant rate over a dedicated channel the native Ethernet network may have bit errors All PSNs suffer to some degree from packet loss and this must be compensated when delivering TDM over a PSN 1 2 Product Description The IPM 4SE series is a Multi service TDM and Ethernet Over LAN MAN bridge which transports one two three or four ports of...

Page 8: ...ts based on traditional TDM and popular IP services Figure 1 2 IPM 4SE 4 Port E1 T1 Application 1 6 IPM 4SE Specifications 100M Ethernet Interface Compliant with 802 3 802 3u standards 10 100 BaseT with RJ 45 connector Full duplex Supports Auto Negotiation per IEEE802 3u LED indicators for Ethernet Link status and Activity PDH Interfaces x 4 E1 Interface Data Rate 2 048 Mbit s 50 ppm Line Code HDB...

Page 9: ...18 75 V Power Consumption less than 10W Operating Environment Ambient temperature 0 40 C for indoor application Optional 0 55 C Storage temperature 0 85 C Relative humidity 5 95 non condensing Physical Dimension Height 44 5 mm 1U Width 370 mm Depth 215 mm Weight 2 Kg net 9 ...

Page 10: ...potentially damaged or missing parts Contact our nearest sales representative or our company directly if you detect any damaged or missing parts Improper handling during shipment may cause early failure Notify the shipper or forwarder immediately if the outer package shows signs of dropping or rough handling 2 3 Site Preparation Install the IPM 4SE within reach of an easily accessible grounded AC ...

Page 11: ...utral l Midd 11 ine le Ground DC IN Left V 48V Right V 0V V FG V Middle Frame Ground 36 75VDC IEC C13 line plug Figure 2 2 IEC AC terminal block DC power connector pin assignment 2 6 Rack Installation There are 3 common parts for each IPM 4SE package including 1 set of TDM over IP multiplexer 1 AC power cord If the IPM 4SE is intended for mounting into a rack a pair of L type Steel brackets with 1...

Page 12: ... the alarm or status if association still works Associate NE via IPM 4SE GUI tbd to diagnose if configuration is correct and what status occurs 2 7 2 Basic Troubleshooting If a ping of the remote NE via LAN MAN does not respond then please check the LAN connections and make sure Switch LAN MAN are working If TDM or LAN provides unstable quality of service please check the link performance or acces...

Page 13: ...d on ALM for any of E1 Links or WAN port Status 3 2 2 Reset Button Provides the facility of rebooting the system without powering off 3 2 3 LAN MNT Ethernet Connectors and Indicators The Lan and MNT Ethernet interfaces use an RJ 45 connector with LED indicators There are green and yellow LED indicators Green Link Link Up Down Status Yellow Act TX RX Active Status 3 2 4 Alarm LED Display E1 T1 Inte...

Page 14: ...E LAN MAN TDM TDM Local Loopback Remote Loopback Figure 3 4 IPM 4SE E1 Loopback Mode 3 5 IP Configuration The IP address subnet mask address and Gateway address of the management port MNT should be setup thru RS232 console using CLI commands 3 6 Interface Configuration For the LAN configuration the setting of traffic bandwidth is provided to ensure the quality of service in TDM circuits with 16 th...

Page 15: ...tings if the device is rebooted or powered off on 3 9 Command Line Interface Setup 3 9 1 Using HyperTerminal as Local Console Terminal When logging into the HyperTerm set up the terminal port as follows Bit rate 115200bps Data bit 8 Parity none Stop bit 1 Flow control none Login password admin factory default 3 9 2 Telnet in for Remote Console Terminal If using the Telnet command in an Operation S...

Page 16: ...ip file_name Upgrade Software image file from TFTP server server_ip TFTP server IP address file_name SW image file name EX upgrade 192 168 2 199 ipm130 bin backup tftp_server_ip file_name Backup the system configuration to TFTP server tftp_server_ip the TFTP server IP address file_name the backup file name EX backup 192 168 2 199 ipm4se_co_backup_1 restore tftp_server_ip file_name Restore the syst...

Page 17: ...EX ceschset 1 1 192 168 1 28 Situation 2 Set dest_ip and dest_mac manually EX ceschset 1 1 192 168 1 28 AA BB CC DD EE FF cespwidset ch_no TrPWID PrPWID Set CESoPSN Channel TrPWID and PrPWID ch_no E1 channel number 1 4 TrPWID Transmit PseudoWire ID PrPWID Provision PseudoWire ID EX cespwidset 1 1 1 jitterbd ch_no depth Set CESoPSN Channel Jitter Buffer Depth Initial Jitter DS is 3 ch_no E1 channel...

Page 18: ...321 OUI xx xx xx Config HW SW MAC 1 HW_MAC Config OUI Addr 00 02 AB Config eth0 Addr 00 02 AB 16 CD 13 this is NMS MAC Source Config eth1 Addr 00 02 AB 16 CD 12 this is WAN MAC Source 3 10 2 CO Unit Factory Default Script CO default replace xx xx xx with CPE unit s unique MAC Address gci srcnet 172 16 1 1 255 255 255 0 ipset 192 168 1 11 255 255 255 0 172 16 1 2 ceschset 1 1 172 16 1 2 00 02 AB xx...

Page 19: ...4 4 4 pktsize 1 0 pktsize 2 0 pktsize 3 0 pktsize 4 0 jitterbd 1 1 jitterbd 2 1 jitterbd 3 1 jitterbd 4 1 ceschclkset 1 0 ceschclkset 2 0 ceschclkset 3 0 ceschclkset 4 0 lanset 1 7 csave The factory default scripts allow the units to connect with 4xE1 over any LAN environment To quickly modify these two scripts for your LAN 1 Change the srcnet IP address to the new IP you want for the WAN port 2 C...

Page 20: ...AC address for the local CO unit gci srcnet 172 16 1 2 255 255 255 0 ipset 192 168 2 11 255 255 255 0 172 16 1 1 ceschset 1 1 172 16 1 1 00 02 AB xx xx xx cespwidset 1 1 1 pktsize 1 0 jitterbd 1 1 ceschclkset 1 0 lanset 1 7 csave 3 11 2 Point to Point with Single E1 port 1 Fractional w CRC4 nx64 n 8 active CO Side use the correct MAC address for the remote CPE unit gci srcnet 172 16 1 1 255 255 25...

Page 21: ...if enabled or not cesfe1crc Duplicate these settings on both IPM4SE units For the hex to timeslot bit mask each TS is represented by a bit TS bits 11111111111111111111111111111111 TS 33222222222211111111110000000000 31 0 10987654321098765432109876543210 If we breakup into octets then we can assign hex values 1111 1111 1111 1111 1111 1111 1111 1111 F F F F F F F F So if we want to enable fifteen ti...

Page 22: ...ackets via MNT port the CESoTDM packets will not be delivered to Router for forwarding to the remote side 10 10 1 254 24 00 48 54 5c ca fc 10 10 2 254 24 00 40 f4 47 ba 24 RS 232 115 2k 10 10 1 20 10 10 1 1 24 WAN 10 10 2 1 24 WAN MNT 10 10 3 1 CO CPE MNT 10 10 4 1 CO Side CLI m 4320 0 Set to SW MAC mode CLI csave CLI reboot CLI gci CLI srcnet 10 10 1 1 255 255 255 0 CO_Wan_IP Mask CLI ipset 10 10...

Page 23: ...ast Ethernet FE1 Fractional E1 IEC International Electrotechnical Commission ITU International Telecommunication Union LAN Local Area Network LED Light Emitting Diode L bit Remote Defect Indication LOS LOF PATH Loss of Signal Frame Path Alarm MAC Media Access Control MAN Metro Area Network MIB Management Information Base NE Network Element ODU Out Door Unit OOF Out of Frame PBX Private Branch eXch...

Page 24: ...Appendix 24 This page left blank intentionally ...

Page 25: ......

Page 26: ......

Reviews: