“Vibration” command index
3.2.3.2.1
IO.Vibration=<
config_type
> – Manages device vibrations
Command syntax
$PFAL,IO.Vibration=
Examples
$PFAL,IO.Vibration=hpulse,5000
$PFAL,IO.Vibration=cyclic,500,1000
Responses
E.g.
$SUCCESS
Command description
This command makes the device vibrate, for example, when the device receives a
GSM call, SMS, TCP packet etc.
Parameter description
<config_type>
Configures settings related to generating a vibration on the device.
The
can be set to:
Value
Meaning
high
Continuous vibration.
low
Disables continuous vibration.
hpulse
,<
high_time
>
Vibrates for a period of time given in milliseconds
cyclic
,
,
> Generates cyclic beeps for the given time
periods
and
respectively.
<
high_time
>
Specifies the number of milliseconds to generate a beep.
<
low_time
>
Specifies the number of milliseconds to disable the beep.