Page | 8
Control Protocol
The control protocol consists of a single byte ASCII command without a terminator.
Baud rate: 9600, 8, N, 1
List of Commands:
Command
Description
Command
Description
1
Play file 01audio_Z.wav
B
Play file 11audio_Z.wav
2
Play file 02audio_Z.wav
C
Play file 12audio_Z.wav
3
Play file 03audio_Z.wav
D
Play file 13audio_Z.wav
4
Play file 04audio_Z.wav
E
Play file 14audio_Z.wav
5
Play file 05audio_Z.wav
F
Play file 15audio_Z.wav
6
Play file 06audio_Z.wav
G
Play file 16audio_Z.wav
7
Play file 07audio_Z.wav
H
Play file 17audio_Z.wav
8
Play file 08audio_Z.wav
I
Play file 18audio_Z.wav
9
Play file 09audio_Z.wav
J
Play file 19audio_Z.wav
A
Play file 10audio_Z.wav
K
Play file 20audio_Z.wav
s
Stop playback
q
Max Volume
v
Returns firmware version info
p
Mid Volume
>
Play next (by index)
o
Low Volume
r
Play random file
m
Mute
x
Enable audio loop-thru
?
Query Volume
y
Disable audio loop-thru
Notes:
1.
The 'Z' in the filename refers to the
Interruptible Flag see section on 'File Names' for
more details.
2.
Command can be sent as upper or lower case characters.
3.
Query Volume returns the following:-
a.
0 for Max Volume
b.
16 for Mid Volume
c.
32 for Low Volume
d.
Mute for lowest volume
Volume set via the push buttons will return values between 0 (Max) and 97
(Min). Each button push will increase or decrease value by 2.
Summary of Contents for WavBox