• Transfer attributes
• Byte enables
• Write data
The peripheral bridge selects and captures read data from the peripheral interface and
returns it to the crossbar switch.
The register maps of the peripherals are located on 4-KB boundaries. Each peripheral is
allocated one or more 4-KB block(s) of the memory map.
The AIPS-Lite module uses the data width of accessed peripheral to perform proper data
byte lane routing; bus decomposition (bus sizing) is performed when the access size is
larger than the peripheral's data width.
20.2 Functional description
The peripheral bridge functions as a bus protocol translator between the crossbar switch
and the slave peripheral bus.
The peripheral bridge manages all transactions destined for the attached slave devices and
generates select signals for modules on the peripheral bus by decoding accesses within
the attached address space.
20.2.1 Access support
All combinations of access size and peripheral data port width are supported. An access
that is larger than the target peripheral's data width will be decomposed to multiple,
smaller accesses. Bus decomposition is terminated by a transfer error caused by an access
to an empty register area.
Functional description
KL02 Sub-Family Reference Manual, Rev. 2.1, July 2013