MPC563XM Reference Manual, Rev. 1
902
Freescale Semiconductor
Preliminary—Subject to Change Without Notice
microcode as a branch condition, and may also influence in the Entry Point taken, allowing fast state
decoding. For more details, see
Section 23.4.1.1, “Entry Points
23.4.9.3.2
Comparator and Time Base Selection
TBS1 and TBS2 fields (4-bit wide each) are used to configure the type of the comparator and the time
bases used for match or capture (See
and
). TBS1 can also be used to control the
Output Buffer Enable signal (See
).
Table 23-78. P Flags Operation - FLC
FLC
Meaning
000
clear flag0
001
set flag0
010
clear flag1
011
set flag1
100
copy flag1:flag0 from P[25:24]
101
copy flag1:flag0 from P[27:26]
110
copy flag1:flag0 from P[29:28]
111
no operation (nil)
Table 23-79. Time Base Selection 1 - TBS1
TBS1 bit
2
1
0
TBS1[3] = 0
bitfield
Comparator
selection
Capture
selection
Match TB
selection
0
greater or
equal
TCR1
TCR1
1
equal-only
TCR2
TCR2
TBS1[3] = 1
action
2
1
0
set OBE=1
0
0
0
set OBE=0
0
0
1
do nothing
1
1
1
reserved
all other values
Table 23-80. Time Base Selection 2 - TBS2
TBS2 bit
2
1
0
TBS2[3] = 0
bitfield
Comparator
selection
Capture
selection
Match TB
selection
0
greater or
equal
TCR1
TCR1
1
equal-only
TCR2
TCR2