E0h
CMD_SLOT_BUSY
A second command was sent to a slot
which was already processing a
command
C0h to 81h User Defined
Low byte of error code listed in Annex
80h and
those filling
the gaps
Reserved for future used
7Fh to 01h Index of not supported / incorrect
message parameter
00h
Command not supported
Table 24 – Slot error register when bmCommandStatus = 1
Slot Status register:
Offset Field Size
Value
Description
0
bmICCStatus
2 bits
0, 1, 2 0 – An ICC is Present and active (power
is on and stable, RST is Inactive)
1 – An ICC is present and inactive (not
activated or shut down by hardware
error)
2 – No ICC is Present
3 – RFU
2 bmRFU
4bits
0 RFU
6
bmCommandStatus
2 bits
0, 1, 2 0 – Processed without error
1 – Failed (error code provided by error
register)
2 – Time Extension is requested
3 – RFU
Table 25 – Slot Status register
When the bmCommandStatus field is 0 indicating the command processed without error or
when the bmCommand field is an RFU value, then the slot’s error register is RFU.
When the bmCommandStatus field is 1 indicating the command failed, then the slot’s error
register is set with a signed 8-bit value.
When the bmCommandStatus field is 2, indicating a time extension is requested, then the
slot’s error register contains the multiplier value of BWT when the protocol is T=1 or the
multiplier value of WWT when the protocol is T=0.
Command processed without error: Slot Status register = 0xh
Command failed (error code provided by the error register): Slot Status register = 4xh
Time extension is requested (slot error register = time multiplier): Slot Status register = 80h
x = 0
: Card present and active
x = 1
: Card present and inactive