Page | 37
8.8.11
Get Remote Key Injection Timeout
Command Body:
78 52 01 01
Command Example
STX
Len
Low
Len
High
Command Body
LRC
CHK
SUM
ETX
02
04
00
78 52 01 01
2A
CC
03
Output Hex String: 020400785201012acc03
Response Body:
06 78 01 01 02 <Timeout_H> <Timeout_L>
Response Example
STX Len
Low
Len
High
Response Body
LRC
CHK
SUM
ETX
02 07 00
78 52 01 01 02 00 C0
BC
42
03
Output Hex String: 020700067801010200c0bc4203
In this example, the timing value is 0x00C0 (192 seconds).
8.8.12
Set Date & Time
Command Body:
78 53 01 50 06 <Date Time>
Command Example
STX
Len
Low
Len
High
Command Body
LRC
CHK
SUM
ETX
02
0B
00
78 53 01 50 06
39
F3
03
Output Hex String (example): 020b00785301500616052010305639f303
Where:
<Data Time> is 6 bytes data – Year, Month, Date, Hour, Minute, Second
Item Value Area (BCD Code)
Year 00~99
Month 01~12
Date 01~31
Hour 00~23
Minute 00~59
Second 00~59
Response Body:
06.
Note:
•
If current Date/Time is 2014/08/23 15:24:59, <Date Time> should be 14 08 23 15 24 59 (BCD
Code).
•
The command always valid in Activation IDLE State.
•
2000/01/01 00:00:00 is the base time; device will reject attempts to set this value.
Summary of Contents for SmartPIN L100
Page 11: ...Page 11 5 3 1 L100 Dimensions ...