51
ifm
Device Manual Supplement: Acyclic data records and Command interface (AC14 and AC4S)
2017 / 09
Command channels
>
4.2.9
Command 0x010B – Read date / time / NTP settings
16679
Using this command, the current values for time, date and NTP settings can be read.
>
Command request channel (fieldbus master >>> device)
16712
Offset
Word no.
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
1
UID
2
command number
3 ... 120
The area is completely ignored.
It does not matter whether the data area exists or what data is contained.
>
Command response channel (device >>> fieldbus master)
16713
Offset
Word no.
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
1
reflected user ID
2
reflected command number
3
reserved
Command status
(
→ p.
4
command error code
5
month
day
6
year (byte 2, MSB)
year (byte 1, LSB)
7
minutes
hours
8
reserved
seconds
9
NTP Offset
reserved
NTP
10
NTP server IP address (high byte, net address)
NTP server IP address
11
NTP server IP address
NTP server IP address (low byte, host address)
Legend:
- day
- month
- year
- hours
- minutes
- seconds
→
Command 0x010A – Set parameters of the NTP server
(
- NTP
- NTP Offset
- NTP server IP address
→
Command 0x010A – Set parameters of the NTP server
(
>
Possible command error codes
16714
Error Code
Error
Description
0x00
no error
>