class: 0x25 COMMAND_CLASS_SWITCH_BINARY 

class: 0x63 COMMAND_CLASS_USER_CODE 

 

Not listening Routing SLAVE 

This Z-Wave product will be used as routing slave. Slave nodes are nodes in a Z-Wave network that receive 
commands and perform actions based on the command. This device will always be in sleep mode because it 
works on batteries. In sleep mode the device is not active listening, the device will wake up according to the 
wakeup command class.  
 

Include Initiator 

The include initiator is used when Primary and Inclusion Controllers include nodes into the network. When 
both the include initiator have been activated simultaneously the new node will be included to the network (if 
the node was not included previously).  

Exclude Initiator 

The exclude initiator is used by Primary and Inclusion Controllers to exclude nodes from the network. When 
the exclude initiator and a slave initiator are activated simultaneously, it will result in the slave being excluded 
from the network (and reset to Node ID zero). Even if the slave was not part of the network it will still be reset 
by this action.  

Z-Wave compatibility 

Because this is a Z-Wave device, it means it can co-operate with other Z-Wave devices of other manufacturers. 
It can co-exist in a Z-Wave network existing with product from other manufacturers.  

Hops & Retries 

The Z-Wave range has a range of up to 30 meters in line of sight. This signal is not limited to the 30 meter 
range due to routing the Z-Wave message to other nodes in the network. This way the range of the Z-Wave 
network can be expanded to 150 meters indoors (limit of 4 hops).  
 

class: 0x63 COMMAND_CLASS_USER_CODE 

The purpose of the User Code Command Class is to configure the 

TagReader

 to accept certain RFID Tags or 

codes. This is typically done by some kind of static controller or gateway (for instance the BeNeXt myGate). 
After sending a User Code Set, including a unique User Identifier (UID), the in-use state (0x01) and the Tag 
code or keypad sequence using ASCII codes, the 

TagReader

 will accept the codes and notify any other device 

using the Alarm Command Class. 
This other device can be configured using the Association Command Class and is typically the same controller 
or gateway. 
When a tag or code is not known to the 

TagReader

, it will send an unsolicited report to the devices in its 

association group with the UID 0x00. The value in this message can be used to configure new tags. 
 

Note:

 Code length must be 4 to 10 ASCII digits. 

 

class: 0x86 COMMAND_CLASS_VERSION 

This Command Class is used to obtain information about the 

TagReader

. The Z-Wave library type, the Z-Wave 

protocol version and the application version will be reported.  
 

class: 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 

This will report information about the manufacturer. This product will contain the manufacturer ID of 

BeNeXt

Summary of Contents for BeNext

Page 1: ...e manual code buttons if you do not press any manual code buttons the tag reader will be starting up and you have 6 seconds to show a RFID Tag in front of the reader With a controller you can request the battery level Mounting 1 Before mount the Tag Reader should be included into a Z Wave network and associated 2 Use a flat screwdriver at the inlets on the sides to gently unlock the back cover 3 U...

Page 2: ...statuses of the device as follows 1 Ready for learn mode indicator light blinks every second 2 Learn in progress add indicator light 2 times every second 3 Learn in progress remove indicator light 3 times every 1 5 second 4 Learn mode success indicator light is on for one second 5 Tamper released indicator light blinks 6 times rapidly 6 Mounting successful indicator light is on for 1 second 7 RF m...

Page 3: ...eadable on the Tags the TagReader has some special procedures Some examples are given at the Typical operation diagrams chapter in the Technical Manual There are some situations 1 In case an unknown Manual Code entered or unknown Tag presented In this case the TagReader will send an unsolicited USER_CODE_REPORT with UserID 0 and UserID Status 0 A controller will receive this report and can initiat...

Page 4: ...ther manufacturers Hops Retries The Z Wave range has a range of up to 30 meters in line of sight This signal is not limited to the 30 meter range due to routing the Z Wave message to other nodes in the network This way the range of the Z Wave network can be expanded to 150 meters indoors limit of 4 hops class 0x63 COMMAND_CLASS_USER_CODE The purpose of the User Code Command Class is to configure t...

Page 5: ...l always be lower then the previous sent value The battery level in the report is maximum 2 lower then the previous sent value class 0x85 COMMAND_CLASS_ASSOCIATION The Association Command Class is used to associate the TagReader to other devices When a tag or code is read the TagReader will send a notification to the Z Wave devices in its association group It will also report the state of the tamp...

Page 6: ...ed Size 1 byte 3 Feedback timeout Description To configure the timeout to wait for a WAKEUP_NO_MORE_INFORMATION before the error beep is automatically sound The error beeps are fixed 8 beeps shortly after each other Default 0x00 Param1 0x00 means disabled Param2 3 4 not used Size 1 byte 4 Feedback beeps per second Description To configure the number of beeps per second Every beep is fixed about 10...

Page 7: ...COMMAND_CLASS_ALARM_V2 In the TagReader this Command Class has two purposes 1 Identify the state of the tamper alarm The device will send an unsolicited report to the devices in its association group if tempering is detected The state of the tamper alarm can also be requested by any other device 2 Report tags or codes that are entered The TagReader will send an unsolicited report to the devices in...

Page 8: ...Value 0xAA Configuration of the device is untouched Note that this value will not change to 0x55 upon modifying the wake up interval and that re setting the value to 0xAA will always reset the wake up interval Always awake mode The always awake mode is used to request different values from the device e g version and manufacturer specific Note in always awake mode the batteries will be drain very f...

Page 9: ...3 Notification sound and acknowledgement enabled configuration parameter 3 set to acknowledgement timeout In the first mode any Basic or Switch Binary commands that are received are ignored The second mode the default can be used to inform a user that the alarm system is armed or disarmed To use this you can send a Basic or Switch Binary set on 0xFF after receiving an Alarm Report and the Wake Up ...

Page 10: ...he user action that is required and the messages which are being sent from to the TagReader for several basic operations including optional functionality as the sound notification and UID acknowledgement Configure a new tag for configuring new codes you can skip directly to the WAKE_UP_NOTIFICATION ...

Page 11: ...Version 0 5 19 December 2012 www iHome eu Arm the alarm system ...

Page 12: ...Version 0 5 19 December 2012 www iHome eu Disarm the alarm system ...

Page 13: ...s not in Include or exclude mode the TagReader will not be included or excluded 2 The TagReader is already included in a Z Wave network Exclude the TagReader and Try to include it again Q I have configured a value but when I request it it is not changed A It is mandatory that the correct size is used while configure a parameter go to the documentation about the configuration command class to check...

Reviews: