72
Chapter 3 - Device Profile
CD1-k – CANopen Communication Profile
Quick stop option code Action
0
Disable drive function
1
Slow down on slow down ramp
3
Slow down on current limit
The slow down ramp is defined in object 3300h.
The slow down current limit is defined in object 3302h.
3.13.2.8 - Object 3302h: Inhibit Current limit
Index 3302h
Name
Inhibit Current limit
Object Code
VAR
Data Type
Unsigned16
Object Class
pp ip hm pv eg
Access rw
Unit
Percentage of amplifier rating (3FFFh = 100%)
Default Value
3FFFh
If "Inhibit Stop Option Code" = 3 (see object 305A), when the INHIBIT input is activated, the motor is slowed down
in velocity loop with this current limitation.
3.13.2.9 - Object 3310h: Low Speed Threshold
The Low Speed Threshold defines the maximum speed authorized in low speed mode (LOW SPEED Input is
activated). If the motor speed is higher, a LowSpeed error will occur and the motor will be slowed down with the
defined stop.
Index 3310h
Name
Low Speed Threshold
Object Code
VAR
Data Type
Unsigned32
Object Class
all
Access rw
PDO Mapping
No
Unit inc/s
3.13.2.10 - Object 3320h: Motor Temperature Sensor
This object defines the parameters for temperature error detection by a motor temperature sensor.
Index 3320h
Name
Motor Temperature Sensor
Object Code
ARRAY
Number of Elements
3
Value Description
Sub Index
1
Description
Sensor Type (CTN/CTP)
Data Type
Unsigned8
Object Class
all
Access rw
PDO Mapping
No
Default Value
eeprom
This parameter defines the sensor type for error detection: 0 means CTN and 1 means CTP.