True Scale Fabric Switches 12000 Series CLI
July 2015
Reference Guide
Order Number: G91931004US
85
12000 Series CLI
Sample Output
-> XEdge-> smLooptestMinISLRedundancy 3
XEdge-> topology_loopTest: DONE
Notes
Use this command to set the minimum number of loops (default=4) to include each ISL
for the SM Loop Test in Fast Mode. This command is only applicable if running the Loop
Test in Fast Mode.
2.5.5.63
smLooptestShowLoopPaths
Displays the loop paths for the SM Loop Test.
Syntax
smLooptestShowLoopPaths [<node index>]
Options
<node index>
–
The node index of the node to print the loop paths.
Sample Output
-> XEdge-> smLooptestShowLoopPaths
Node Idx: 0, Guid: 0x00066a00e3002711 Desc Intel 12200 GUID=0x00066a00e3002711
--------------------------------------------------------------------------
Node Node Node Path
Idx Lid NODE GUID #Ports LID PATH[n:p->n:p]
---- ------ ------------------ ------ ------ ---------------
0 0x0001 0x00066a00e3002711 36 0x0040 0:9->0:33
0 0x0001 0x00066a00e3002711 36 0x0042 0:33->0:9
--------------------------------------------------------------------------
There are 2 total loop paths of <=4 links in length in the fabric!
Two LIDs are used per loop path to inject packets in clockwise and anti-clockwise
directions
Notes
Use this command to print the loop paths through a node specified by node index, or all
nodes (default) for the SM Loop Test.
2.5.5.64
smLooptestShowSwitchLft
Displays the switch LFT for the SM Loop Test.
Syntax
smLooptestShowSwitchLft [<node index>]