Kramer Electronics Ltd.
VM-10H2
– Protocol 3000
24
GEDID
Functions
Permission
Transparency
Set:
GEDID
Administrator
Public
Get:
GEDID?
End User
Public
Description
Syntax
Set:
Set EDID data from device
#GEDID
SP
stage
,
stage_id
CR
Get:
Get EDID support on certain input/output
#GEDID?
SP
stage
,
stage_id
CR
Response
Set:
Multi-line response:
~
nn
@GEDID
SP
stage
,
stage_id
,
size
CR LF
EDID_data
CR LF
~
nn
@GEDID
SP
stage
,
stage_id
SP
OK
CR LF
Get:
~
nn
@GEDID
SP
stage
,
stage_id
,
size
CR LF
Parameters
stage
– input/output
0 - Input
1 - Output
2 - Default EDID
3 - Custom EDID
stage_id
– number of chosen stage (1.. max number of inputs/outputs)
size
– EDID data size. For Set, size of data to be sent from device, for Get, 0 means no EDID support
Response Triggers
Response is sent to the com port from which the Set (before execution) / Get command was received
Notes
For Get, size=0 means EDID is not supported
For old devices that do not support this command, ~
nn
@ERR 002
CR LF
is received
K-Config Example
Set EDID data from device connected to OUT 1:
“#GEDID 1,1
”,0x0D