20
Set SWR threshold, Command code 50 - 56. Set the threshold for a "good" tune to SWR values
between 1.1 and 3.0. Tunes ending at SWR values above the threshold will not be saved to
memory.
Command Code
SWR Threshold
50 1.1
51 1.3
52 1.5
53 1.7
54 2.0
55 2.5
56 3.0
Reset relays, Command code 57. Resets all L, C and the Hi/Lo Z relays.
Automatic tuning on, Command code 58. Sets automatic tuning on.
Automatic tuning off, Command code 59. Sets automatic tuning off.
Request forward power, Command code 60. Requests tuner to report the forward RF power.
Request reflected power, Command code 61. Requests tuner to report the reflected RF power.
Request SWR, Command code 62. Requests tuner to report the SWR.
Turn live updates on, Command code 63. Turns live updates on if previous turned off.
Turn live updates off, Command code 64. Disable live updates of forward and reflected power,
SWR and frequency (defaults to On at power up).
Set inductor value, Command code 65. Parameter 1: inductor value 0 - 127. Manually sets
inductor values.
Set capacitor value, Command code 66. Parameter 1: capacitor value 0 - 127. Manually sets
capacitor values.