27
64 = lighting button 9 (on only when loco is reversing)
65 = button 1 (on only when loco is reversing)
128 = lighting button 9 (on only when loco is
moving forward)
129 = button 1 (on only when loco is moving forward)
(depends on loco model, do not change, as functions
can be affected or destroyed)
CV52
Command for front lighting terminal (see CV51)
[128]
CV53
Command for rear lighting terminal (see CV51)
[64]
CV54
LGB configuration
[10]
Bit programming
Bit 1: hand-off function, 0 = off, 1 = on [0]
Bit 2: MTS Back-EMF, 0 = off, 2 = on [2]
Bit 3: analog Back-EMF, 0 = off, 4 = on [0]
Bit 4: load-dependent chuffs, 0 = off, 8 = on [8]
Bit 5: 0 = F1 constant, 16 = F1 flashing [0]
Bit 6: 0 = F2 constant, 32 = F2 flashing [0]
Bit 7: 0 = two chuffs/revolution, 64 = four chuffs [0]
Bit 8: automatic brake sounds, 0 = on, 128 = off [0]
To program, add the values for the individual Bits and
program the resulting function value. The values for
Bits 5-8 vary between locos. The values for your loco
can be read using the 55045 MTS PC Decoder
Programming Module.
Hand-off function on: When operating with 55015,
you can adjust direction and speed for two seconds after
selecting a moving loco without causing the loco to stop.
CV55
Reset factory pre-set values for CVs
Program:
6-55->
5-55->
CV56
Voltage for function terminal F2
(1-32)
[5]
(depends on loco model, do not change, as functions
can be affected or destroyed)
CV57
Command for function terminal F2 (see CV51)
[15]
CV58
Pause time (analog operation) (0.5 seconds x function
(0-255)
[0]
value)
When the polarity of the analog track voltage is
reversed, the loco waits for the programmed time
period, then accelerates in the new direction
CV59
F button for half-speed mode
(0-8)
[0]
If CV59 is programmed to a value between 1 and 8, the
respective function button will trigger the half-speed mode.
Function value 0: half-speed mode not active.
CV60
Back-EMF: Max. adjustment factor
(1-255)
[4]
Specifies the max. increase or decrease of voltage applied
during each time interval (programmed in CV61)
1 = small steps, 255 = large steps
The factory pre-set values of CV60 and CV61 are
optimized for LGB motors.