Page 94
Appendix | EtherCAT Documentation
optoNCDT 1900 / EtherCAT
A 5.3.2.8
Object 3852: Load, Save
3852
RECORD Measurement settings
Subindices
0
VAR
Number of entries
6
UINT8
ro
1
VAR
Current
x
STRING(32)
ro
2
VAR
Read
x
STRING(32)
wo
3
VAR
Store
x
STRING(32)
wo
4
VAR
Delete
x
STRING(32)
wo
5
VAR
Initial
x
STRING(32)
rw
6
VAR
List
x
STRING(230)
ro
- Current: Contains the currently used user program (setup) in the
String
field.
- Read: Read loads a measuring program and activates it, enter the setup name in the
String
field and confirm with
OK
.
- Store: Store saves a measuring program, enter the setup name in the
String
field and confirm with
OK
.
- Delete: Enter setup name in the
String
field and confirm with
OK
- Initial: Displays the user program to be loaded when the sensor is started.
- List: Displays the names of the user programs (setups).
A 5.3.2.9
Object 3900: Sensor Information
3900
RECORD Sensor information
Subindices
0
VAR
Number of entries
2
UINT8
ro
1
VAR
Measuring range
x
FLOAT
ro
2
VAR
Option
x
STRING32
ro
- Measuring range: measuring range of the sensor
- Option: contains the option number of the sensor
Summary of Contents for ILD1900-10