69
DETAILS OF INPUT AND
OUTPUT SIGNALS
7
Monitor Alarm definition
Read H0074 to
H0077
H0000 to HFFFF: Last two alarm definitions
Refer to the alarm data table
(page 72)
Set frequency (RAM)
Read
H006D
Read set frequency/speed from RAM or EEPROM.
⋅
H0000 to HFFFF:
Set frequency...0.01Hz increments
Speed ..............Unit r/min (when
Pr.37
= 1 to 9998 or
Pr.144
= 2 to
10, 102 to 110)
⋅
When performing torque control under real sensorless vector
control or vector control with
Pr.544
= "0, 1, 12, (100, 112, 114)" and
Pr.804
= "3 or 5", read torque command value.
The setting range depends on
Pr.804
. (FR-A700 series)
Set frequency (EEPROM)
H006E
Set frequency (RAM)
Write
H00ED
Write set frequency/speed to RAM or EEPROM.
⋅
H0000 to H9C40 (0 to 400.00Hz) :
Frequency........0.01Hz increments
⋅
H0000 to H270E (0 to 9998) :
Speed ..............Unit r/min (when
Pr.37
= 1 to 9998 or
Pr.144
= 2 to
10, 102 to 110)
⋅
To change the set frequency consecutively, write data to the
inverter RAM. (Instruction code: HED)
⋅
When performing torque control under real sensorless vector
control or vector control (torque control) with
Pr.544
= "0, 1, 12,
(100, 112, 114)" and
Pr.804
= "3 or 5", torque command is set.
The setting range depends on
Pr.804
. (FR-A700 series)
Set frequency
(RAM and EEPROM)
Write
H00EE
*4
Setting from remote resisters can be made.
Item
Read /
Write
Code
Number
Description
b15
b8 b7
b0
Latest alarm
Second alarm in past
Third alarm in past
Fourth alarm in past
Fifth alarm in past
Sixth alarm in past
Seventh alarm in past
Eighth alarm in past
H74
H75
H76
H77