Moog ACV with CANopen bus interface
7 Servo valve functions
Pressure setpoint conditioning / demand value generator
B99224-DV018-D-211, Rev. A, October 2018
163
7.4.5.1 Object 0x63B0: Type
This parameter defines the progression of the ramp.
Value description
7.4.5.2 One-quadrant ramp (ramp type 1)
This function limits the input signal's rate of change to the defined <AccelerationTime> (0x63B1).
This ramp type is active, if the parameter <Type> (0x63B0) is set to 1.
Figure 75: Ramp type 1
ValvePressureControl_DemandValueGenerator_Ramp
Index
Sub-index
Parameter name
Data type
Access
Per-
sistence
Value range
Default
0x63B0
0
Type
INT8
rw
Y
0…3
0
<Type>
Description
0
No ramp
1
One-quadrant ramp
2
Two-quadrant ramp
3
Four-quadrant ramp
Table 79: Possible values of parameter <Type> (0x63B0)
t
input
+ 100 %
- 100 %
t
output
+ 100 %
- 100 %
<AccelerationTime>
(0x63B1)