Moog ACV with CANopen bus interface
7 Servo valve functions
Axis velocity setpoint conditioning / demand value generator
B99224-DV018-D-211, Rev. A, October 2018
206
7.8.23 Signal limitation
The output of the controller is limited to ±16384 (±100 %).
Figure 113: Signal limitation
7.9 Axis velocity setpoint conditioning / demand value
generator
Figure 114: Axis velocity setpoint conditioning / demand value generator
7.9.1 Object 0x5615: Demand value
The demand value indicated by this parameter is generated from the #AxisVelocitySetpoint# by means of the
functions in the demand value generator and forwarded to the axis velocity controller.
Chapter "2.4.3 Units and prefix parameter", page 12
<P
os
iti
on
C
ont
ro
lle
rO
ut
pu
t>
(0x5
50F
)
#C
o
nt
ro
lle
rO
ut
pu
t2
#
Velocity
demand value generator
Limit function
Ramp
#AxisVelocitySetpoint#
<VelDemamdValue>
(0x5615)
The internal signal #AxisVelocitySetpoint# is used to link the pressure setpoint value to the axis
velocity demand value generator.
Chapter "6.2.6 Axis velocity setpoint value path", page 67
ValveVelocityControl_DemandValueGenerator
Index
Sub-index
Parameter name
Data type
Access
Per-
sis-
tence
Value range
Default
0x5615
1
VelDemandValue
INT32
ro
N
INT32
None
0x5615
2
Unit
UINT8
ro
-
UINT8
0
0x5615
3
Prefix
INT8
ro
-
INT8
0