Moog ACV with CANopen bus interface
6 Signal routing and scaling
Setpoint value path
B99224-DV018-D-211, Rev. A, October 2018
64
6.2.5.2 Object 0x3330: Setpoint parameter
The axis position setpoint value parameter <PosSetpointParameter> (0x3330) points to the input where the
axis position setpoint value <PosSetpoint> (0x6600) comes from.
The axis position setpoint value <PosSetpoint> (0x6600) is only effective in case the <StatusWord> (0x6041)
is 1111
b
('ACTIVE') and the <DeviceMode> (0x6042) is set to 1 (setpoint input via bus).
Value description
This pointer contains a combination of index, sub-index and length of the parameter to be used.
The default value is 0x66000120, which refers to the <PosSetpoint> (0x6600), sub-index 0x01 with the length
of 32 bit (32 = 0x20).
6.2.5.3 Object 0x6614: Hold setpoint
This parameter defines the axis position hold setpoint value. This parameter is in effect only for the
<ControlMode> (0x6043) = 8 (axis position control).
Chapter "7.1.1 Object 0x6043: Control mode", page 128
The <PosHoldSetpoint> (0x6614) acts as setpoint value in case of <StatusWord> (0x6041) equals 'HOLD' or
'FAULT_HOLD'.
Chapter "5.2.3 Object 0x6041: Status word", page 52
Chapter "2.4.3 Units and prefix parameter", page 12
DrivePositionControl
Index
Sub-index
Parameter name
Data type
Access
Per-
sistence
Value
range
Default
0x3300
0x00
PosSetpointParameter
INT32
rw
Y
INT32
0x66000120
<PosSetpointParameter>
Byte
3
2
1
0
Description
Index MSB
Index LSB
Sub-Index
Parameter bit length
Default
0x63
0x80
0x01
0x20
Table 35: Possible values of parameter <PosSetpointParameter> (0x3300)
DrivePositionControl
Index
Sub-index
Parameter name
Data type
Access
Per-
sistence
Value
range
Default
0x6614
1
PosHoldSetpoint
INT32
rw
Y
INT32
0
0x6614
2
Unit
UINT8
ro
-
UINT8
0
0x6614
3
Prefix
INT8
ro
-
INT8
0