Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
Subindex
01
h
Name
Index Of 1st Feedback Interface
Data type
UNSIGNED16
Access
read only
PDO mapping
TX-PDO
Allowed values
Preset value
3380
h
Subindex
02
h
Name
Index Of 2nd Feedback Interface
Data type
UNSIGNED16
Access
read only
PDO mapping
TX-PDO
Allowed values
Preset value
33A0
h
Subindex
03
h
Name
Index Of 3rd Feedback Interface
Data type
UNSIGNED16
Access
read only
PDO mapping
TX-PDO
Allowed values
Preset value
33B4
h
Description
The subindices have the following function:
•
00
h
: Value="1" to "n", where "n" is the number of existing feedbacks.
•
n
h
:
Subindex n refers to the index of the respective object for the configuration of the corresponding
feedback.
Subindex 01
h
always corresponds to the first (and always existing) sensorless feedback.
3210h Motor Drive Parameter Set
Function
Contains the P and I components of the current, speed and position controllers for open loop (only
current controller activated) and closed loop.
Object description
Index
3210
h
Object name
Motor Drive Parameter Set
Object Code
ARRAY
Data type
UNSIGNED32
Savable
yes, category: application
Version: 1.0.1 / FIR-v1748
189