Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
Data type
UNSIGNED32
Access
read / write
PDO mapping
TX-PDO
Allowed values
Preset value
00000000
h
Description
•
Subindex 01
h
: This is used to select the type of level change:
•
Deactivate function: Value "0"
•
With rising edge: Value "1"
•
With falling edge: Value "2"
•
Both edges: Value "3"
•
Subindex 02
h
: Specifies the number of the noted level changes since the time the function was
started; is reset to 0 if subindex 01
h
is set to 1,2 or 3
•
Subindex 03
h
: Encoder position of the level change (in absolute user units from 6064
h
)
•
Subindex 04
h
: Encoder position of the level change
3242h Digital Input Routing
Function
This object determines the source of the input routing that ends in 60FD
.
Object description
Index
3242
h
Object name
Digital Input Routing
Object Code
ARRAY
Data type
UNSIGNED8
Savable
yes, category: application
Access
read only
PDO mapping
no
Allowed values
Preset value
Firmware version
FIR-v1504
Change history
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
24
h
Version: 1.0.1 / FIR-v1748
202