Chapter 9
Digital Routing and Clock Generation
9-10
ni.com
The filter setting for each input can be configured independently. On power
up, the filters are disabled. Figure 9-4 shows an example of a low to high
transition on an input that has its filter set to 125 ns (N = 5).
Figure 9-4.
Filter Example
Enabling filters introduces jitter on the input signal. For the 125 ns and
6.425
μ
s filter settings, the jitter is up to 25 ns. On the 2.56 ms setting,
the jitter is up to 10.025
μ
s.
When a PFI input is routed directly to RTSI, or a RTSI input is routed
directly to PFI, the S Series device does not use the filtered version of the
input signal.
Refer to the KnowledgeBase document,
Digital Filtering with M Series
and CompactDAQ
, for more information about digital filters and counters.
To access this KnowledgeBase, go to
ni.com/info
and enter the info
code
rddfms
.
Routing Signals in Software
Table 9-4 lists the basic functions you can use to route signals.
Note
For more information about routing signals in software, refer to the
NI-DAQmx Help
or the
LabVIEW Help
in version 8.0 or later.
Table 9-4.
Signal Routing in Software
Language
Function
LabVIEW and NI-DAQmx
DAQmx Export Signal.vi
and
DAQmx Connect Terminals.vi
C and NI-DAQmx
Export_Signal
and
DAQmx_Connect_Terminals
1 2
3
1 4
1
2
3
4 5