5.5.3 Output control continued
#
Commands
5 :CUR!;
6 :CUR?;
7 :OUTn;
8 :OUT?;
9 :FLDn;
10 :FLD?;
Description
Returns the string
followed by the present programmed output current.
The programmed value range is shown in table 5-2.
example- SA3.000
SA07.50
SA
Returns the string
followed by the actual output current. The actual
current range is the same as the programming range.
example- AA3.000
AA07.50
AA
Sets the output to On or Off.
:OUT1; - Output On
:OUT0; - Output Off
Returns
followed by the output On/Off status.
OT1 - Output is On
OT0 - Output is Off
OT
Sets the Foldback protection to On or Off.
:FLD1; Arm the foldback protection.
:FLD0; Release the foldback protection.
:FLD2; Cancel the foldback protection.
When the foldback protection is activated, :FLD0; will release the
protection and re-arm it while :FLD2; will cancel the protection. If the
protection has not been activated, both commands are the same.
Returns
followed by the Foldback protection status.
FD1 - Foldback is armed
FD0 - Foldback is released
FD
11 :OVPn;
12 :OVP?;
Sets the over-voltage protection level in volts. Over-voltage range settings
are given in table 5-3:
example- :OVP08.4;
example- OP08.4
Returns the string
followed by the present programmed over-voltage
protection value. The over-voltage range is given in table 5-3.
OP
Model
MIN.
MAX.
ZUP6-XY
0.00
7.50
ZUP10-XY
00.0
13.0
ZUP20-XY
00.0
24.0
ZUP36-XY
00.0
40.0
ZUP60-XY
00.0
Table 5-3: Over-voltage programming range.
66.0
44