ENGLISH –
17
7.3 LEVEL 2 PROGRAMMING (ADJUSTABLE PARAMETERS)
All the Level 2 parameters are factory-set as highlighted in “
GREY
” in “
” and can be modified at any time. The parameters
can be set to a scale of 1 to 8. The check the value corresponding to each LED, refer to “
”.
7.3.1 Level 2 programming procedure
m
The user has maximum 10 seconds to press the buttons consecutively during the programming procedure,
after which time the procedure terminates automatically and memorises the changes made up to then.
To perform Level 2 programming:
1.
press and hold the
g
button until LED “
L1
” starts flashing
2.
release the
g
button when LED “
L1
” starts flashing
3.
press the
f
or
h
button to move the flashing LED to the “
entry LED
” associated with the parameter to be
modified
4.
press and hold the
g
button. With the
g
button pressed:
–
wait roughly 3 seconds, until the LED representing the current level of the parameter to be modified lights up
–
press the
f
or
h
button to shift the LED associated with the parameter’s value
5.
release the
g
button
6.
wait 10 seconds (maximum time) to exit the programming mode.
l
To set multiple parameters during the procedure's execution, repeat the operations from point 2 to point 4 dur-
ing the phase itself.
l
The set value highlighted in grey (“Table 6”) indicates that this value is the factory setting.
Table 6
LEVEL 2 FUNCTIONS (ADJUSTABLE PARAMETERS)
Entry
LED
Parameter
LED
(level)
Set value
Description
L1
Pause Time
L1
5 seconds
Adjusts the pause time,
i.e. the time before
automatic re-closure.
Is effective only if
“Automatic Closing” is
enabled.
L2
15 seconds
L3
30 seconds
L4
45 seconds
L5
60 seconds
L6
80 seconds
L7
120 seconds
L8
180 seconds
L2
Step-by-Step
function
L1
Open - Stop - Close - Stop
Controls the sequence of
commands associated
with the “SbS”, “Open”
and “Close” inputs or the
radio control.
[
Note :
] by setting L4,
L5, L7 and L8, also the
behaviour of the “Open”
and “Close” commands
is modified.
L2
Open - Stop - Close - Open
L3
Open - Close - Open - Close
L4
Condominium: during the
opening manoeuvre
the “Step-by-Step” and
“Open” commands do not cause any effect, while the “Close” command
causes the movement to reverse, namely closing of the leaves; during
the
closing manoeuvre
the “Step-by-Step” and “Open” commands
cause the movement to reverse, namely opening of the leaves, while the
“Close” command does not cause any effect.
L5
Condominium 2: during the
opening manoeuvre
the “Step-by-Step”
and “Open” commands do not cause any effect, while the “Close”
command causes the movement to reverse, namely closing of the gate
leaves. If the sent command remains for more than 2 seconds, a “Stop”
command is executed. During the
closing manoeuvre
the “Step-by-
Step” and “Open” commands cause the movement to reverse, namely
opening of the leaves, while the “Close” command does not cause any
effect. If the sent command remains for more than 2 seconds, a “Stop”
command is executed.
L6
Step-by-Step 2 (less than 2 sec triggers “Partial Open”)
L7
Hold-to-run: the manoeuvre is only executed if the sent command
remains; if it is interrupted, the manoeuvre stops.
L8
Opening in “semi-automatic” mode, closing in “hold-to-run” mode
L3
Motor speed
L1
Very slow
Adjusts the motor
speed during normal
manoeuvres.
L2
Slow
L3
Medium
L4
Fast
L5
Very fast
L6
Extremely fast
L7
Opens “Fast”; closes “Slow”
L8
Opens “Extremely fast”; closes “Medium”