 Properties 

Property 

Description 

Input Mode 

Input Range 

Data Type 

Default 

General 

Name 

Object name. Must not be overlapped 
in a screen. 

Direct input 

Character 
string (1 to 
127) 

LEDStatus_Monitor0 

Type 

Object type. Not changeable. 

GI_S_D_Monitor_IA
G_12inch.LEDStatu
s_Monitor 

Version 

IAG version 

1.0.0.0 

Publisher 

IAG publisher 

Omron Promotion 
Sample 

Appearance 

Background Color 

Background color of a page 

Item 
selection 
Direct input 

Color pallet 
Character 
string 

Transparent

1

 

Layout 

▼Position (Left , Top)

 

Position setting of an object in a page.

2

 

Direct input 
Spin button 

Numeric 
Numeric 

Left 

Horizontal position (X-axis) of the 
top-left corner of an object on a page 

Direct input 
Spin button 

Numeric 
Numeric 

Top 

Vertical position (Y-axis) of the to-left 
corner of an object on a page 

Direct input 
Spin button 

Numeric 
Numeric 

▼Size (Width, Height)

 

Object size setting. 

Direct input 
Spin button 

Numeric 
Numeric 

1240,660

 

Width 

Width of object 

Direct input 
Spin button 

Numeric 
Numeric 

1240 

Height 

Height of object 

Direct input 
Spin button 

Numeric 
Numeric 

660 

Input/Output 

SelectDeviceIPAddress 

IP address of the displayed unit 

Variable 
specification 

String 

(Blank) 

PreviousPageName 

Page name that changes after the end 
of this page 

Variable 
specification 

String 

(Blank) 

ExitMonitor 

The flag to exit GI-S Monitor 

Variable 
specification 

Boolean 

(Blank) 

Image 

 

 

1: Transparent 
2: The origin of coordinates locates at the top left corner of NA screen. 

 

   Precautions for Correct Use

 

In the usage described in this document, do not set the In/Out variables “ExitMonitor” 

and leave them blank to avoid unintended behaviors. 

 

 

Summary of Contents for NA5-12 101 Series

Page 1: ...Programmable Terminal NA Series Practice Guide IAG Collection for GI S Safety I O Terminal Unit Monitor NA5 15 101 NA5 12 101 V456 E1 01 ...

Page 2: ...se IAG objects It does not provide safety information for an entire system Be sure to obtain the manuals for NA Series Programmable Terminal read and understand the safety points and other information required for use and test sufficiently before actual use of the equipment ...

Page 3: ... separately Combined conditions are not warranted Reference data is intended to be used just for reference Omron does NOT guarantee that the Omron Product can work properly in the range of reference data Examples are intended for reference Omron does not warrant the conformity in usage of the examples Omron may discontinue Omron products or change specifications of them because of improvements or ...

Page 4: ...th potential of chemical contamination or electromagnetic interference facilities with vibration or impact facilities on continual operation for a long period d Applications under conditions or environment which are not described in the catalogues Omron products in the catalogues are not intended to be used in automotive applications including two wheel vehicles Please DO NOT use Omron products in...

Page 5: ...mages arisen from or relating to Omron products Export Control Customers of Omron products shall comply with all applicable laws and regulations of other relevant countries regarding security export control in exporting Omron products and or technical documents or in providing such products and or documents to a non resident Omron products and or technical documents may not be provided to customer...

Page 6: ...and Conditions Agreements 3 Table of Contents 6 1 Related Manuals 7 2 Precautions 8 3 Overview 9 3 1 Overview 9 3 2 System Configuration 10 4 Library Versions 11 5 IAG Descriptions 12 5 1 LEDStatus_Monitor 12 Revision History 21 ...

Page 7: ...V118 NA5 15W NA5 12W NA5 9W NA5 7W Programmable Terminal NA Series Software USER S MANUAL V119 NA5 15W NA5 12W NA5 9W NA5 7W Programmable Terminal NA Series Device Connection USER S MANUAL V120 NA5 15W NA5 12W NA5 9W NA5 7W Programmable Terminal NA Series STARTUP GUIDE W504 SYSMAC SE2 Sysmac Studio Version 1 OPERATION MANUAL ...

Page 8: ...in 3 2 System Configuration However Omron does not guarantee screen operations after embedding the IAGs Special information in this document is classified as follows Precautions for Safe Use Describes precautions on what to do and what not to do to ensure proper operation and performance Precautions for Correct Use Describes precautions on what to do and what not to do to ensure proper operation a...

Page 9: ...connected with NA Series HMI IAG external specifications IAG installation on a screen IAG Icon Description LEDStatus_Monitor Monitors LED statuses The IAG is included in the IAG collection file below File name Description GI_S_D_Monitor_IAG_12inch_RevA iag For RevA the underlined letter stands for version Ask an Omron sales representative for the file ...

Page 10: ...C Sysmac Studio Sysmac Studio projects with IAGs Screen Transfer NA Series NX7 Series NX CSG320 Ring Node 1783 ETAP Rockwell Automation GI S Series EtherNet IP NX102 Series NJ Series DLR supporting device CIP Safety on EtherNet IP devices Controller Ring Super Visor DLR R SV Ring Node DLR R N NXR ILM Series ...

Page 11: ...imum supported HMI version in IAG Collections Manager NA OS The version which NA runtime can operate It differs according to NA s Runtime version System Menu of NA It will be checked if necessary when you upgrade NA runtime version of a project in Sysmac Studio Versions of IAG collection NA runtime and OS in this guide Item Version Remarks IAG Collection Ver1 00 Filename extension is iag IAG Noted...

Page 12: ... and displays the device information of the GI S Series Safety I O Terminal Unit Shows error details and solutions that LEDs indicate Detects and notifies failed communications between NA and GI S Series Safety I O Terminal Unit Graphics This IAG consists of one screen and three pop up windows LED Status Screen Communication Error Window Communication error Error Details and Solutions Window Devic...

Page 13: ...Display Selected Safety I O Terminal Unit s IP address is displayed 3 Label Displays LED indicator s updating status 4 Data Lamp Represents selected Safety I O Terminal Unit s power LEDs and safety I O LEDs 5 Button Displays Error Details Window 6 Button Displays Device Information Window 7 Label Displays Communication Error Window when a communication error occurs Layout Properties Default Descri...

Page 14: ... LEDs stand for and the solutions for them User I F Specifications No Part Description 1 Button Displays the previous page 2 Button Displays the next page 3 Button Closes this window Layout Properties Default Description Position Left Up Fixed Size Width Height Fixed 1 2 3 ...

Page 15: ... NA and Safety I O Terminal Unit has been failed and quits displaying this IAG User I F Specifications No Part Description 1 Button Switches to the page with the name of the PreviousPageName variable Layout Properties Default Description Position Left Up Fixed Size Width Height Fixed 1 ...

Page 16: ... displayed 2 Data Display Unit version is displayed 3 Data Display Lot number is displayed 4 Data Display Serial number is displayed 5 Data Display Hardware version is displayed 6 Data Display MAC address is displayed 7 Button Closes this window Layout Properties Default Description Position Left Up Fixed Size Width Height Fixed 1 7 2 3 4 5 6 ...

Page 17: ...ic Numeric Top Vertical position Y axis of the to left corner of an object on a page Direct input Spin button Numeric Numeric Size Width Height Object size setting Direct input Spin button Numeric Numeric 1240 660 Width Width of object Direct input Spin button Numeric Numeric 1240 Height Height of object Direct input Spin button Numeric Numeric 660 Input Output SelectDeviceIPAddress IP address of ...

Page 18: ...rsion History IAG version Description IAG collection version 1 0 0 0 First edition Ver1 00 Events Actions No events and actions Animations Basic motions can be defined Security No security function available ...

Page 19: ... Event Description SelectGI_S Executed when a GI Series Unit is selected Property Assignment for IAG on the page before transition Assign the following properties Input Output of IAG EtherNet_IP_NetworkMonitor or IAG DLR_Monitor to the following variable Property Input Output Description Variable Name Data Type SelectDeviceIPAddress IP address of the displayed unit SelectDeviceAddress String Curre...

Page 20: ...ed Screen previous screen1 Screen with IAG When the event that GI S Unit is selected in the IAG on the page before transition occurs the selected IP address and page name before transition are fetched When Back button is pressed the screen switches to the screen where IAG EtherNet_IP_NetworkMonior is placed Back Related Screen previous screen2 When GI S Unit is pressed in the IAG on the page befor...

Page 21: ...21 Revision History Revision Code Date Revision Description 01 February 2020 First edition ...

Page 22: ...7 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Kyoto JAPAN OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 OMRON CHINA CO LTD Room 2211 Bank of China Tower 200 Yin Cheng Zhong...

Reviews: