87
3-7 Bar Code/2D Code Settings Commands
3-7-1 Bar code/2D code characters (by ASCII code): BCS
Sets the characters to encode of the bar code/2D code objects by the ASCII code. Alpha-numeric characters and symbols
are available.
⿎
Setting request data / response data for readout
Start
code
BCS
Sub
command
[Object No.] [String No.] [Code data]
At setting: Max. 33-byte
At readout: Max. 63-byte
(Check
sum)
End code
Sub command is “S” for the setting request data and “A” for the response data for readout.
⿎
Readout request data
Start
code
BCS
R
[Object No.] [String No.]
2-byte or
3-byte (2D side of composite code)
(Check
sum)
End code
⿎
Data description
Name
(> Name in LP-400/V)
Data length
[byte]
Data contents
Remarks
Object No.
(> Bar code No.)
1
“0”–“7”: Object No. 1100 to 1107
String No.
1
or
2
For bar code/ 1D side of composite
code:
“1”–“2”
• The string No. is applied to the linefeed
of the human readable character. The
linefeed is not included in the code data.
• If the code data length is more than 30-
byte, set the character in the several
string No. They are connected together
in numerical order without linefeed to
create the code data.
• For EAN/UPC/JAN or 1D side of GS1
DataBar Limited/Stacked, set “1” always.
• Only for 2D side of the composite code,
set this item with 2-byte length.
For 2D code:
“1”–“9”
For 2D side of composite code:
“01”–“09”
Code data
Min. 0
Max. 30
Input Method: ASCII code
• Functional characters cannot be used.
• Specify 0-byte for data length to delete
characters.
• If the readout data includes characters
that cannot be expressed in ASCII code
such as Japanese characters (2-byte
character), only these 2-byte characters
are read out in shift JIS code.
• If the code data contains any functional
characters or 2-byte characters, the
maximum readout data can be 60-byte.
Total data length
Max. 32
or
Max. 33
Variable length.
• For bar code/2D code/1D side of composite code: Max. 32-byte
• For 2D side of composite code: Max. 33-byte
• Response data for readout: Max. 63-byte
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...