Remote-Control Commands
R&S
®
SMCVB-K164
129
User Manual 1179.0974.02 ─ 02
6.8.3
Data Cell Commands
Example: Querying the number of data cells
:SOURce1:BB:T2DVb:INFO:DP?
// Response: "1637178
// Maximum number of PLP data cells per T2 frame is 1637178.
:SOURce1:BB:T2DVb:INFO:DPUSed?
// Response: "1636200"
// Current T2 frame has 1636200 data cells.
Commands
[:SOURce<hw>]:BB:T2DVb:INFO:DP?
.............................................................................129
[:SOURce<hw>]:BB:T2DVb:INFO:DPUSed?
.....................................................................129
[:SOURce<hw>]:BB:T2DVb:INFO:DP?
Queries the maximum possible number of PLP data cells in the T2 frame.
Return values:
<Dplp>
integer
Range:
0 to 1E7
*RST:
0
Example:
See
Example "Querying the number of data cells"
Usage:
Query only
Manual operation:
See
"PLP Data Cells Per T2 Frame (D
[:SOURce<hw>]:BB:T2DVb:INFO:DPUSed?
Queries the current number of PLP data cells in the T2 frame.
Return values:
<Dplpused>
integer
Range:
0 to 1E7
*RST:
0
Example:
See
Example "Querying the number of data cells"
Usage:
Query only
Manual operation:
See
"PLP Data Cells in Current T2 Frame (D
6.9
TSGen Subsystem
The
TSGen
subsystem contains the commands for configuring the TS player.
TSGen Subsystem