Parameter
Name
Type
Range
Default
<bool>
Bool
{0|1}
0
Remarks
•
*PSC 1 denotes clearing the enable registers of the Status Byte and Standard
Event registers at power-on; *PSC 0 denotes that the enable registers of the
Status Byte and Standard Event registers will not be affected at power-on.
•
(*ESE 0) to clear the enable registers of
the Status Byte and Standard Event registers respectively.
Return Format
The query returns 0 or 1.
Examples
*PSC 1 /*Enables the function of clearing the enable registers of
the Status Byte and Standard Event registers at power-on.*/
*PSC? /*Queries the on/off state of the function of clearing the
registers at power-on. The query returns 1.*/
4.3.8
*RCL
Syntax
*RCL
<
n>
Description
Recalls a previously stored instrument state from the internal memory.
Parameter
Name
Type
Range
Default
<n>
Discrete
{0|1|2|3|4|5|6|7|8|9}
-
Remarks
•
This command recalls a previously stored state from the power supply’s
internal memory. Using number from 0 to 9 can recall the states named
RIGOL0.RSF~RIGOL9.RSF respectively.
Command System
26
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.