If <source> is omitted, the command clears an OVP event that occurred on the
current channel.
•
[:SOURce[<n>]]:VOLTage:PROTection:CLEar
to clear an OVP
event that occurred on the specified channel and enable the channel output.
•
to query whether an
OVP event has occurred on the specified channel.
Return Format
None.
Examples
:OUTP:OVP:CLE CH1 /*Clears an OVP event that occurred on CH1.*/
4.8.12
:OUTPut:OVP[:STATe]
Syntax
:OUTPut:OVP[:STATe]
[<
source>,]<bool>
:OUTPut:OVP[:STATe]?
[<
source>]
Description
Sets or queries the on/off state of the overvoltage protection (OVP) function of the
specified channel.
Parameter
Name
Type
Range
Default
<source>
Discrete
{CH1|CH2|CH3}
-
<bool>
Bool
{0|1|ON|OFF}
0
Remarks
•
When OVP is enabled, the output is disabled automatically if the output voltage
reaches the OVP level (
) currently set. You can
send
to query whether an OVP
event occurred on the specified channel.
•
If <source> is omitted, the command executes the corresponding operation on
the current channel.
Return Format
The query returns 1 or 0.