2/22/2018
ROBOTIS e-Manual
http://emanual.robotis.com/docs/en/dxl/x/xm430-w210/
12/34
2. 4. 9. Protocol Version(13)
Users can select Dynamixel protocol version (1.0 and 2.0). It is
recommended to use an identical protocol version for
multiple Dynamixels.
Value
Protocol
Version
Compatible Dynamixels
1
1.0
AX Series, DX Series, RX Series, EX Series, MX
Series with Firmware below v39
2(default)
2.0
MX-28/64/106 with Firmware v39 or above, X
Series, Pro Series
Note
The protocol 2.0 is greatly enhanced from the protocol 1.0.
Accessing some of the Control Table area might be denied if
protocol 1.0 is selected. This manual complies with protocol 2.0.
Please refer to the
section of e-Manual for more details
about the protocol.
2. 4. 10. Homing Offset(20)
Users can adjust the Home position by setting Home
Offset(20). The Homing Offset value is added to the Present
Position(132). Present Position(132) = Actual Po
Homing Offset(20).
Unit
Value Range
Description
about 0.088°
-1,044,479 ~ 1,044,479
(-255 ~ 255[rev])
4,096 resolution
Note
In case of the Position Control Mode(Joint Mode) that
rotates less than 360 degrees, any invalid Homing Offset(20)
values will be ignored(valid range : -1,024 ~ 1,024).
2. 4. 11. Moving Threshold(24)
This value helps to determine whether the Dynamixel is in
motion or not.
When the absolute value of Present Velocity(128) is greater
than the Moving Threshold(24), Moving(122) is set to ‘1’,
otherwise it is cleared to ‘0’.
Values
Description
Unit
about 0.229 rpm All velocity related Data uses the same unit
Range
0 ~ 1,023
-
2. 4. 12. Temperature Limit(31)
Back to Top ▲