xCode
1234
xRegOut
0
Note: If the password was changed from the „default” factory 1234 to another (e.g.
6543), the SMS has to be 6543 on (6543 off).
8.2
Remote control of heating regulation on a cottage
The electrical appliance is connected to output OUT of GSM-R2-T using a contactor.
SMS message in the following format sets the requested temperature to 25 ° C for
temperature regulator and activates the function “regulator”:
1234 temp25
The proper function depends on the following parameters on a SIM card:
The default factory setting is not necessary to change:
xCode
1234
xReg
1
xRegHyst
1
xRegIn
1
xRegOut
0
8.3
Entry gate opening by phone call from a mobile
phone (without confirmation)
The gate control is connected to output OUT of GSM-R2-T. After the first ringing from
the phone number from which was sent the first valid SMS command GSM-R2-T
rejects a call and the entrance gate will open. The next call will close the entrance
gate.
Correct function is affected by following parameters on the SIM card (items in the
phone book); default parameters need not to be changed:
xIo0pulseLen
4
(note.: o0 = "ó" and "zero")
xRemDout
0
xRemCall
1
xRemConfirm
0
xMaster
+420777111111
If you need to control the entry gate using different phone numbers, add these
numbers on SIM card:
xRUser1
+420777222222
xRUserPeter
+420777333333
Note. It’s possible to append characters to „xRUser“ for better identification of a
user’s phone number.
8.4
Entry gate opening by call from a mobile phone
(with confirmation)
After the first ringing from the phone number which is in the list of users (xRUser. ..)
of the GSM-R2-T, it rejects a call and calls back. When the calling user rejects the call
within 29 seconds, the entrance gate will open.
The setting of parameters on a SIM card is the same as it the previous chapter (8.3),
except xRemConfirm parameter which must be set to "1":
xRemConfirm 1
9.
Event SMS Messages
Whenever any event appears on the GSM-R2-T input or output for longer than
minimum specified time, the GSM-R2-T sends an SMS about this event. To increase
the probability the user will read the SMS it can be followed by a voice call from GSM-
R2-T. See the xe[...+...+.....] parameters.
If you answer the phone call you will hear a voice message in a form of DTMF signals.
10.
Examples of event messages
The following examples describe the most common examples of what can GSM-R2-T
to send to you. All the examples are based on the "default" parameter settings on the
SIM card (see Chapter 6).
10.1
SMS message based on input event (an input
IN1 is activated by voltage)
By applying a voltage to the input IN1 (= input is activated) is sent the following SMS
text:
GSM R2 T: In1 ALARM!
out=on
in1=on
Sig=64%
Temp=ERROR
As a phone number is used the phone number from which was sent the first valid SMS
(in this example is used phone 420777111111).
Correct function is affected by following parameters on the SIM card (items in the
phone book); default parameters, which need not to be changed:
xMaster
+420777111111
If you need to send the SMS message to other phone numbers, you must add them to
the SIM card phone book:
xRUser1
+420777222222
xRUserPetr
+420777333333
10.2
Call when the voltage disappears from input
IN1
By disconnecting the voltage from the input IN1 (= input is deactivated) the phone
number from which was sent the first valid SMS (+420777111111 in this example) is
called.
Correct function is affected by following parameters on the SIM card (items in the
phone book); default parameters, which need not to be changed:
xeI1+HL+CALL
+420777111111
10.3
SMS when the temperature drops
If you want to receive SMS when the temperature drops below +5 ° C, it is necessary
to set these parameters on the SIM card:
xeA1+HL+SMS
+420777111111
xAIn1Level
10
xAIn1Hyst
5
Level (Level) is set to 10 ° C, the hysteresis (Hyst) at 5 ° C. SMS is sent when the
temperature drops below +5 ° C (+10 ° C - 5 ° C). The SMS is re-sent after the
temperature rose above +15 ° C (10 ° C + 5 ° C) and then falls below +5 ° C again.
11.
Advanced functions
11.1
Automatic Voice Call
Automatic voice call enables to verify the ability of the GSM-R2-T to make a voice call
in case of any event (i.e., functionality, the credit, the GSM signal etc.).
In the following example the GSM-R2-T will call you between 9:00 and 18:00 of a local
time. It means you will not be woken up in the middle of night. If you will not answer
the call, the GSM-R2-T will repeat the call after 2 minutes again.
Example of parameters on a SIM card:
xAutoCall =
+420123456789 … (= call the phone 420123456789)
xAutoCallInt =
1 … (= call every month)
xAutoCallIntFrom =
9 … (= call between 9 am
xAutoCallIntTo =
18 and 6 pm)
Format of
xAutoCallInt
parameter is: 1 = 1 month, #2 = 2 days, *3 = hours, 1#2*3
= 1 month 2 days 3 hours. The time period between calls starts whenever new value
of the parameter is set (it happens when the SIM card is inserted into GSM-R2-T and
the power supply is set on).
11.2
Automatic SMS message
This function is useful for reporting “I am alive” and inputs and outputs status via SMS
messages. You can set a phone number to send automatic SMS message (xAutoSms),
time
period
between
two
SMS
messages
(
xAutoSmsInt
),
begin
(
xAutoSmsIntFrom
) and end (
xAutoSmsIntTo
) time, when automatic SMS
message is allowed to be sent.
Example of parameters on a SIM card:
GSM-R2-T sends SMS message every day between 18:00 and 21:00.
xAutoSms =
+420123456789 … (= send SMS toe phone 420123456789)
xAutoSmsInt =
#1 … (= send an SMS every day)
xAutoSmsIntFrom =
18 … (= send an SMS between 6 pm
xAutoSmsIntTo =
21 and 9 pm)
Format of
xAutoSmsInt
parameter is: 1 = 1 month, #2 = 2 days, *3 = hours,
1#2*3 = 1 month 2 days 3 hours. The time period between SMS starts whenever new
value of the parameter is set (it happens when the SIM card is inserted into GSM-R2-T
and the power supply is set on).
After saving parameters on the SIM card the GSM-R2-T sends an SMS with the
following text:
GSM R2 T: Device OK. .... followed by status information.