INITIAL CONFIGURATION
The SMINN GSM B can work in di erent, parameterizable modes. It is advisable to
con gure the device via SMS or USB using the GSMTool application, if available. If
using GSMTool, do not connect the SIM card and power the device via USB.
In any case, it is advisable to start out adding the rst user (see USER
MANAGEMENT), which will be, unless changed, the device master user. Additionally,
it is also advisable to change the administration password (the default one is
'0000'). If no user is added to the device it will work in public mode, granting access
to any call to its phone number via the K2 relay.
MANEUVER MODES
The device can work in any of three maneuver modes:
Two channels:
This mode activates the relay assigned to each user upon
receiving a call. It is useful in installations with two devices or two distinct modes.
X and Z are the con gured timings for the signals in each relay.
Open / Close
: This mode uses the K2 relay to open the gate upon receiving a call
and the K1 relay to close the gate upon receiving the next call. It is possible to
specify an override security time to close the gate automatically; if left unspeci ed
the gate must be closed via phone call.
X is the con gured timing for the opening signal in the K2 relay, Y is the security
override timing to close the gate automatically and Z is the con gured timing for the
closing signal in the K1 relay. If Y is set with '0' the gate will only close via phone call.
Autom
a
tic
cicle
:
This mode uses the relay assigned to each user to open the gate
upon receiving a call and waits a con gured time before using the same relay to
close the gate. It is possible to override the waiting time via a phone call. If the
waiting time is not set the gate will only close via a phone call.
X is the con gured timing for the opening signal, Y is the delay to close the gate
automatically and Z is the con gured timing for the closing signal. If Y is set with '0'
the gate will only close via phone call.
DIGITALS INPUTS
The SMINN GSM B receiver has two con gurable digital inputs for alarm use. Each
input can be con gured independently with the following parameters:
- Contact type: Normally Open contact / Normally Closed contact
- ON time: Time the input has to be activated to produce an alarm
- OFF time: Time the input has to be deactivated to stop producing an
alarm.
- Restore time: Time since an alarm has stopped until a new alarm can be
produced.
Alarms produce SMS texts for all subscribed users. The SMS text can be customized
for each input.
USER MANAGEMENT
The device is available in di erent models for 100, 200, 450, 1000 and 2000 users.
The rst user to be added is the device master, which can be changed later. The
master user can use any con guration SMS. The system supports any number of
administrator users aside from the master.
Users can be added via a call pressing the PROG button, via SMS or via GSMTool.
Each user will be added with the following information:
- Phone number: The system supports up to 15 digits with international
pre x (ITU-T E.164 recommendation)
- Access relay: Relay that will be used in two channel and automatic cycle
modes.
- Timetable: Hour interval in which the system will grant access to the user.
It can be unlimited.
- Use limit: Number of accesses the system will grant to the user. It can be
unlimited.
- Administrator: Establishes whether the user is an administrator or a normal
user.
- Enabled: Establishes whether the user is enabled in the device or not.
- Inputs: Alarm input subscription for the user.
Administrator users can use most of the con guration SMS and can, therefore,
manage the device.
ACCESS EVENTS
The SMINN GSM B receiver has a rotative event memory for up to 8000 events.
Those events can only be read using the GSMTool application via USB. For the event
system to work the device needs to be con gured with the correct date and time
(see SMS GUIDE) and have a button battery instaled to keep the clock going when
power is out. The battery must be installed with the device powered on.
SMS GUIDE
Con guration SMS are only valid for adminsitrator users and the master user. All
comma separated parameters can be ommited both selectively (omitting just a
parameter but leaving the commas) or from a parameter onward (ending the
con guration message early). Phone numbers only support numbers and the +
character for the internation pre x, if used.
Ex:#0000#NEWU#+3495789056#B,2@ -> Not written parameters will tak their
default values
#0000#NEWU#+3495789056#B,2,,,0,23@ -> UM and USES will take their default
values
Add/Modify user
The same SMS can both add or modify a user.
#
PASSWD
#NEWU#
NUM
#
IN,RL,UM,USES,START,END
@
PASSWD: 4 character administration password
NUM: User phone number. Maximum 16 digits with international code.
IN: 1 if the user is to be subscribed to the rst input.
2 if the user is to be subscribed to the second input.
B if the user is to be subscribed to both inputs.
N if the user will not be subscribed to any input.
Default value
RL: 1 to assign the K1 relay to he user.
2 to assign the K2 relay to the user.
Default value
UM: U if it is a normal user.
Default value
M if it is an administrator user.
USES: Access limit forthe user; Between 1 and 254, 255 means unlimited
accesses.
Default value: 255
START: Initial hour for the timetable; between 0 and 23.
Default value: 0
END: End hour for the timetable; between 1 and 24.
Default value: 24
Ex: #0000#NEWU#+34957489056#B,2,U,255,0,23@
Delete user
The master user cannot be deleted; to delete the master user you must change the
master.
#
PASSWD
#DELU#
NUM
@
Ex: #0000#DELU#957849056@
Block user
A blocked user is still con gured in the system but is not granted access while
blocked. The master user cannot be blocked.
#
PASSWD
#BLCK#
NUM
@
Ex: #0000#BLCK#957489056@
Unblock user
Allows to unblock a user.
#
PASSWD
#UBLK#
NUM
@
Ex: #0000#UBLK#957849056@
Password change
The password must be 4 alphanumeric characters.
#
PASSWD
#MODP#
NEWPASSWD
@
Ex:#0000#MODP#1234@
User replacement
Changes the phone number of an existing user keeping its con guration. The user
master cannot be replaced this way (See Master replacement later).
#
PASSWD
#REPL#
OLDNUM
#
NEWNUM
@
OLDNUM: Old user phone number. Maximum 15 digits with international code
NEWNUM: New user phone number. Maximum 15 digits with international code
Ex: #0000#REPL#957894056#917344557@
PROG button block
#PASSWD
#PRGEN#
MODE
@
MODE: ON to allow registration via button. OFF to disallow it.
Memory format
This message is only valid for the master user
#
PASSWD
#FORMAT#
ID_MEM
@
PASSWD: 4 character administration password
IDMEM: U to format the user memory
L to format the event memory
B to format both memories
Ex:#0000#FORMAT#L@
Master replacement
This message is only valid for the master user
#
PASSWD
#NEWM#
OLDNUM
#
NEWNUM
@
NEWNUM: New master user number.
Maximum 15 digits with international code
Ex: #0000#NEWM#957894056#917434557@
Mode con guration
#
PASSWD
#MODE#
M,T1,T2,T3
@
PASSWD: 4 character administration password
M: 2-CNL for two channel mode.
Default value
C-AUT for automatic cycle mode
OP-CL for open/close mode.
T1: Time in seconds for the opening pulse in the K2 relay for two channel
mode (X) or for the corresponding relay in the other modes (X).
Between 1 and 255 seconds
T2: Time in seconds for the opening pulse in the K1 relay for two channel
mode (Z) or delay between opening and closing for the rest of the
modes (Y). Between 0 and 255 seconds if Y and between 1 and 255
seconds if Z
T3: Time in seconds for the closing pulse for automatic cycle and
open/close modes (Z). This parameter must not be used for two
channel mode. Between 1 and 255 seconds
Default times are: 2 seconds for X and Z
10 seconds for Y.
Ex:#0000#MODE#C-AUT,3,30,2@
Input con guration
#
PASSWD
#PLRTY#
INx
#
MODE,TON,TOFF,TRSTR,BASE
@
INx: IN1 to con gure the rst digital input
IN2 to con gure the second
MODE: OFF to deactivate the digital input.
Default value
NC for normally closed contact with SMS.
NO for normally open contact with SMS.
NC-C for normally closed contact with lost call (GSM B 3G only).
NO-C for normally open contact with lost call (GSM B 3G only).
TON: Time the input has to be active to produce an alarm. Between 10 and
990.
Default value: 150
TOFF: Time the input has to be inactive to stop producing an alarm.
Between 10 and 990
. Default value: 150
TRSTR: Time interval during which the input is ignored after an alarm has been
produced. Between 1 and 99 minutes.
Default value: 5 minutes
BASE: Time base for TON and TOFF.
0 for msec., 1 for sec. and 2 for min.
Default value: 0 (msec.)
Ex: #0000#PLRTY#IN2#NC,70,200,5,0@
Alarm SMS
con guration
#
PASSWD
#CNFG#
SMS IN-x
#
TEXT
@
SMS IN-x: SMS IN-1 for the rst digital input or SMS IN-2 for the second
TEXT: Text that is sent to subscribed users when an alarm is produced. Max
120 characters
Ex:#0000#CNFG#SMS IN-1#FIRE ALARM IN WORK PLACE@
Date con guration
#
PASSWD
#UPDATE#
Y,M,D,H,MN,S
@
PASSWD: 4 character administration password
Y: Date year in 2 or 4 digits
M: Date month (between 1 and 12)
D: Date day (between 1 and 31)
H: Date hour (between 0 and 23)
MN: Date minute (between 0 and 59)
S: Date second (between 0 and 59)
Ex:#0000#UPDATE#03,1,14,17,53,28@ (January 14th, 2013 17:53:28)
Input status
#STATUS@
Relay activaction
#
RLx
#ON#
TIME
@
o
#
IN-x
#ON@
RLx: RL1 for relay 1, RL2 for relay 2
TIME: Time in secs. If not set it uses the one con gured with the mode.
GSM SIM CARD´S PIN REQUEST MUST BE DISABLED FOR THE SYSTEM TO WORK