background image

INITIAL CONFIGURATION

The SMINN GSM B can work in di erent, parameterizable modes. It is advisable to 
con gure the device via SMS or USB using the GSMTool application, if available. If 
using GSMTool, do not connect the SIM card and power the device via USB.
In any case, it is advisable to start out adding the  rst user (see USER 
MANAGEMENT), which will be, unless changed, the device master user. Additionally, 
it is also advisable to change the administration password (the default one is 
'0000'). If no user is added to the device it will work in public mode, granting access 
to any call to its phone number via the K2 relay.

MANEUVER MODES

The device can work in any of three maneuver modes:
     

Two channels: 

This mode activates the relay assigned to each user upon 

receiving a call. It is useful in installations with two devices or two distinct modes.

X and Z are the con gured timings for the signals in each relay.

     

Open / Close

: This mode uses the K2 relay to open the gate upon receiving a call 

and the K1 relay to close the gate upon receiving the next call. It is possible to 
specify an override security time to close the gate automatically; if left unspeci ed 
the gate must be closed via phone call.

X is the con gured timing for the opening signal in the K2 relay, Y is the security 
override timing to close the gate automatically and Z is the con gured timing for the 
closing signal in the K1 relay. If Y is set with '0' the gate will only close via phone call.

    

Autom

a

tic

 cicle

This mode uses the relay assigned to each user to open the gate 

upon receiving a call and waits a con gured time before using the same relay to 
close the gate. It is possible to override the waiting time via a phone call. If the 
waiting time is not set the gate will only close via a phone call.

X is the con gured timing for the opening signal, Y is the delay to close the gate 
automatically and Z is the con gured timing for the closing signal. If Y is set with '0' 
the gate will only close via phone call.

DIGITALS INPUTS

The SMINN GSM B receiver has two con gurable digital inputs for alarm use. Each 
input can be con gured independently with the following parameters:
 

- Contact type: Normally Open contact / Normally Closed contact

 

- ON time: Time the input has to be activated to produce an alarm

 

- OFF time: Time the input has to be deactivated to stop producing an 

 

                    alarm.

 

- Restore time: Time since an alarm has stopped until a new alarm can be 

 

 

            produced.

Alarms produce SMS texts for all subscribed users. The SMS text can be customized 
for each input.

USER MANAGEMENT

The device is available in di erent models for 100, 200, 450, 1000 and 2000 users. 
The  rst user to be added is the device master, which can be changed later. The 
master user can use any con guration SMS. The system supports any number of 
administrator users aside from the master.
Users can be added via a call pressing the PROG button, via SMS or via GSMTool.

Each user will be added with the following information:
 

- Phone number: The system supports up to 15 digits with international 

 

                             pre x (ITU-T E.164 recommendation)

 

- Access relay: Relay that will be used in two channel and automatic cycle 

 

 

           modes.

 

- Timetable: Hour interval in which the system will grant access to the user. 

 

 

       It can be unlimited.

 

- Use limit: Number of accesses the system will grant to the user. It can be 

 

 

    unlimited.

 

- Administrator: Establishes whether the user is an administrator or a normal 

 

 

             user.

 

- Enabled: Establishes whether the user is enabled in the device or not.

 

- Inputs: Alarm input subscription for the user.

Administrator users can use most of the con guration SMS and can, therefore, 
manage the device.

ACCESS EVENTS

The SMINN GSM B receiver has a rotative event memory for up to 8000 events. 
Those events can only be read using the GSMTool application via USB. For the event 
system to work the device needs to be con gured with the correct date and time 
(see SMS GUIDE) and have a button battery instaled to keep the clock going when 
power is out. The battery must be installed with the device powered on.

SMS GUIDE

Con guration SMS are only valid for adminsitrator users and the master user. All 
comma separated parameters can be ommited both selectively (omitting just a 
parameter but leaving the commas) or from a parameter onward (ending the 
con guration message early). Phone numbers only support numbers and the + 
character for the internation pre x, if used.
Ex:#0000#NEWU#+3495789056#B,2@ -> Not written parameters will tak their 
default values
#0000#NEWU#+3495789056#B,2,,,0,23@ -> UM and USES will take their default 
values

Add/Modify user

The same SMS can both add or modify a user.

 

#

PASSWD

#NEWU#

NUM

#

IN,RL,UM,USES,START,END

@

    PASSWD: 4 character administration password
           NUM: User phone number. Maximum 16 digits with international code.
 

 IN: 1 if the user is to be subscribed to the  rst input.

 

      2 if the user is to be subscribed to the second input.

 

      B if the user is to be subscribed to both inputs.

 

      N if the user will not be subscribed to any input. 

Default value

 

RL: 1 to assign the K1 relay to he user.

 

      2 to assign the K2 relay to the user. 

Default value

 

UM: U if it is a normal user. 

Default value

 

       M if it is an administrator user.

          USES: Access limit forthe user; Between 1 and 254, 255 means unlimited 
 

           accesses. 

Default value: 255

        START: Initial hour for the timetable; between 0 and 23. 

Default value: 0

            END: End hour for the timetable; between 1 and 24. 

Default value: 24

Ex: #0000#NEWU#+34957489056#B,2,U,255,0,23@

Delete user

The master user cannot be deleted; to delete the master user you must change the 
master.

#

PASSWD

#DELU#

NUM

@

Ex: #0000#DELU#957849056@

Block user

A blocked user is still con gured in the system but is not granted access while 
blocked. The master user cannot be blocked.

#

PASSWD

#BLCK#

NUM

@

Ex: #0000#BLCK#957489056@

Unblock user

Allows to unblock a user.

#

PASSWD

#UBLK#

NUM

@

Ex: #0000#UBLK#957849056@

Password change

The password must be 4 alphanumeric characters.

#

PASSWD

#MODP#

NEWPASSWD

@

Ex:#0000#MODP#1234@

User replacement

Changes the phone number of an existing user keeping its con guration. The user 
master cannot be replaced this way (See Master replacement later).

#

PASSWD

#REPL#

OLDNUM

#

NEWNUM

@

    OLDNUM: Old user phone number. Maximum 15 digits with international code
   NEWNUM: New user phone number. Maximum 15 digits with international code

Ex: #0000#REPL#957894056#917344557@

PROG button block

#PASSWD

#PRGEN#

MODE

@

        MODE: ON to allow registration via button. OFF to disallow it. 

Memory format

This message is only valid for the master user

#

PASSWD

#FORMAT#

ID_MEM

@

    PASSWD: 4 character administration password
        IDMEM: U to format the user memory
 

       L to format the event memory

 

       B to format both memories

Ex:#0000#FORMAT#L@

Master replacement

This message is only valid for the master user

#

PASSWD

#NEWM#

OLDNUM

#

NEWNUM

@

   NEWNUM: New master user number.
 

        Maximum 15 digits with international code

Ex: #0000#NEWM#957894056#917434557@

Mode con guration

#

PASSWD

#MODE#

M,T1,T2,T3

@

    PASSWD: 4 character administration password
 

  M: 2-CNL for two channel mode. 

Default value

 

       C-AUT for automatic cycle mode

 

       OP-CL for open/close mode.  

 

  T1: Time in seconds for the opening pulse in the K2 relay for two channel 

 

        mode (X) or for the corresponding relay in the other modes (X). 

 

       Between 1 and 255 seconds

 

 T2: Time in seconds for the opening pulse in the K1 relay for two channel 

 

       mode (Z) or delay between opening and closing for the rest of the 

 

       modes (Y). Between 0 and 255 seconds if Y and between 1 and 255 

 

       seconds if Z

 

 T3: Time in seconds for the closing pulse for automatic cycle and 

 

       open/close modes (Z). This parameter must not be used for two 

                     channel mode. Between 1 and 255 seconds

 

      Default times are: 2 seconds for X and Z

 

 

 

        10 seconds for Y.

Ex:#0000#MODE#C-AUT,3,30,2@

Input con guration

#

PASSWD

#PLRTY#

INx

#

MODE,TON,TOFF,TRSTR,BASE

@

 

INx: IN1 to con gure the  rst digital input

 

       IN2 to con gure the second

         MODE: OFF to deactivate the digital input. 

Default value

 

       NC for normally closed contact with SMS.

 

       NO for normally open contact with SMS.

                     NC-C for normally closed contact with lost call (GSM B 3G only).
                     NO-C for normally open contact with lost call (GSM B 3G only).
            TON: Time the input has to be active to produce an alarm. Between 10 and 
 

        990. 

Default value: 150

          TOFF: Time the input has to be inactive to stop producing an alarm. 
 

       Between 10 and 990

. Default value: 150

        TRSTR: Time interval during which the input is ignored after an alarm has been 
 

       produced. Between 1 and 99 minutes. 

Default value: 5 minutes

          BASE: Time base for TON and TOFF.
                     0 for msec., 1 for sec. and 2 for min. 

Default value: 0 (msec.)

Ex: #0000#PLRTY#IN2#NC,70,200,5,0@

Alarm SMS

 con guration

#

PASSWD

#CNFG#

SMS IN-x

#

TEXT

@

    SMS IN-x: SMS IN-1 for the  rst digital input or SMS IN-2 for the second
          TEXT: Text that is sent to subscribed users when an alarm is produced. Max 
                     120 characters
Ex:#0000#CNFG#SMS IN-1#FIRE ALARM IN WORK PLACE@

Date con guration

#

PASSWD

#UPDATE#

Y,M,D,H,MN,S

@

    PASSWD: 4 character administration password
 

   Y: Date year in 2 or 4 digits

 

   M: Date month (between 1 and 12)

 

   D: Date day (between 1 and 31)

 

   H: Date hour (between 0 and 23)

 

MN: Date minute (between 0 and 59)

 

   S: Date second (between 0 and 59)

Ex:#0000#UPDATE#03,1,14,17,53,28@ (January 14th, 2013 17:53:28)

Input status
#STATUS@

Relay activaction
#

RLx

#ON#

TIME

o

 #

IN-x

#ON@

             RLx: RL1 for relay 1, RL2 for relay 2
           TIME: Time in secs. If not set it uses the one con gured with the mode.  

GSM SIM CARD´S PIN REQUEST MUST BE DISABLED FOR THE SYSTEM TO WORK

Reviews: