RS-485 Remote Control Protocol
Page 6-10
Reference Guide: SM6610, SM6615, SM6620 and SM6625 Satellite Modulators
ST.RE.E10152.2
6.3.5 Save
Configuration
This message downloads a configuration to the Modulator to one of the
save locations 1 - 8.
Table 6.7: Save Configuration
Size
Type
0x81
2
Value
Configuration Number
0x01 - 0x08
2
Configuration Name (TEXT)
Unused bytes set to NUL
(ASCII 0)
20
Protocol
Version
0x00 - 0xFF
(See Section 6.8 Protocol Version)
2
Input Select
0x00 - SPI
0x01 - ASI 1
0x02 - Reserved
0x03 - ASI 2
0x04 - ASI 3
0x05 - ASI 4
0x10 - Test packets (Null)
0x11 - Test packets (PRBS)
2
Reserved
Set to 0x00
2
Packet Size
0x00 - 204 byte
0x01 - 188 byte
2
Reserved
Set to 0x00
2
Bit-rate
Set interface bit-rate in 1 bit/s increments. This
value is only used if Symbol rate is set to
0xFFFFFFFF.
e.g. 155 Mbit/s = 0x093D1CC0
8
Symbol
rate
Set symbol rate in 1 symbol/s increments. This
value is used by default unless set to
0xFFFFFFFF in which case bit-rate will be used.
e.g. 30 Msymbol/s = 0x01C9C380
8
FEC rate
0x00 - Reserved
0x01 - Reserved
0x02 - Reserved
0x03 - 1/2
0x04 - 2/3
0x05 - 3/4
0x06 - 5/6
0x07 - 7/8
0x08 - 8/9
2
Modulation/coding mode
0x00 - Reserved
0x01 - DVB
2
Modulation format
0x00 - QPSK
0x01 - BPSK
0x02 - 8PSK
0x03 - 16QAM
2