9
Table of SMS commands
identif. par.
command body example
description
SMS reply
Note
ALARM
1 to 8
, phone number )
1
42060212311
adding or change of phone number at positioni par.
"OK"
ALARM
1 to 8
,
ALARM2,
erasing phone number on position par
"OK"
ADMIN
phone number )
1
ADMIN,+42060212311
adding or change of phone number ADMIN
"OK"
ADMIN
erasing phone number ADMIN
"OK"
#1111#POLOHA
#1111#POLOHA
request for identification of position
position
PERMIT,DDMM,ddm
, DDMM,ddmm
PERMIT,3105,0206
permission for data access for 1 hour to memory of recorde
d position . For transmission will be selected period betwee
n dates DDMM and ddmm
"OK"
CAR
, OF
CAR,OF
deactivation of unit ( unit react then for SMS "STAT" and "
CAR,ON" only from ADMIN number
"OK"
ADMIN only
CAR
, ON
CAR,ON
unit activation
"OK"
ADMIN only
BLOCK
, ON
BLOCK,ON
closing of output for blocking (switch off ignition)
for closing must be valid position reading and speed under
15 km/h
"OK"
BLOCK
, OF
BLOCK,OF
unblocking
"OK"
RST
RST
unit restart
"OK"
STAT
STAT
identification of unit status
programm version
ABCDE
Backup=x.xxV
Battery=yy.yV
Mode act
Block on (Block of)
credit
A=blok (1 ON)
B=key (1 od.)
C=alarm (1 on)
D=GPS (0 -off)
E=ignition
ALTIM
, tt*bb*pp*uu
05*10*02*35
Remote setting of unit parametres
"OK"
parametres in
previous table
CAL
, ATD603123456
;
CAL,ATD603123456
;
unit generate a call to set number immediatelly after receivi
ng )
2
"OK" - call established
"NO CARRIER" - unreachable
"BUSY" - busy
CAL
, ATH
CAL,ATH
zaøízení ukonèí probíhající hovor
CAL
, AT+CPAS
CAL,AT+CPAS
identification of unit status
"+CPAS: 0" - stand by
"+CPAS: 3" - incoming call
"+CPAS: 4" - current beying call
CAL
, AT+CSQ
CAL,AT+CSQ
identification of signal strength
"+CSQ: 17,99" - first number befor
e comma is signal strength(max 32
), min. value for calling is cca 17
CAL
, AT+CPBR=par.
CAL,AT+CPBR=1
identification of phone number on the SIM at certain positio
n par.
+CPBR: 1,"+420602123111",14
5,"ALARM1"
CAL
, AT+CCLK=?
CAL,AT+CCLK=?
clock status in unit
+CCLK:“00/01/01,01:17:36” )
3
because clocks are set to 0 when u
nit is switch off , running since 1.1.
00. It always shows operation time
since last switch off ( short fails are