8.2.3 Object 6003h
– Preset value, single-sensor-operation
Risk of injury and damage to property by an actual value jump when the
Preset adjustment function is performed!
The preset adjustment function should only be performed when the
measuring system is at rest, otherwise the resulting actual value jump must
be permitted in the program and application!
The preset function is used to set the measuring system value to any position value
within the measuring range.
With write access on this object the position value is set to the parameter "Preset
value".
If the value 0xFF FF FF FF is written the preset is cleared. Afterwards the position
which is output refers to the physical zero point of the measuring system (delivery
status).
Index
0x6003
Object type
VAR
Name
Preset value, single-sensor-operation
Data type
INTEGER32
Category
Mandatory
Value range
-
2 147 483 648…+2 147 483 647
Access
rw
Default value 0
PDO mapping
no
Preset value, two's complement
Byte 0
Byte 1
Byte 2
Byte 3
2
7
to 2
0
2
15
to 2
8
2
23
to 2
16
2
31
to 2
24
To facilitate device handling, in case of operation with one magnet only, this object
should be used preferred.
However, it is possible to use also Object 6010h
– Preset values for multi-sensor
devices. For this reason this object is hard-wired with sub-index 1 of object 6010h.
That means that a change in this object causes a change in object 6010h sub-index 1
and vice versa.