Operating the Programmer
18
#abcxxxxxx...xxxxxx<cr>
where
#
start of command character. All commands must start with this
character.
abc
the command
xxx...
user data
<cr>
carriage return
If command execution is successful, the programmer sends the response
#Done<cr>
If command execution is unsuccessful, the programmer sends the response
#Error<cr>
RS–232 Command Set
Programmer commands are listed below. Use these commands by following the
format described in the Command Execution Protocol section above.
Note: You have the option of placing the tag into the tag holder before issuing the
command or you can enter the command and place the tag into the tag holder within
10 seconds. If you do not place the tag in the holder and close the door within 10 sec-
onds, the programmer will abort this command. See
for tag insertion instructions.
Enable Tone Generator (#120<cr>)
The default state of the audible tone generator is tone-enabled. The tone generator
creates audible responses described as a beep, triple beep, and solid tone. This
command re-enables the programmer’s audible response capability after it has been
disabled by the #121 command.
Response:
#Done<cr>
Disable Tone Generator (#121<cr>)
This command disables the programmer’s audible response capability. The default
state of the audible tone generator is tone-enabled.
Response:
#Done<cr>